Skip to content

DavidCho1999/archaiflow-skills / bundles/code-life-safety/skills/applicability-check

applicability-check

Verified

Takes any requirement — a code section, a standard, an ordinance, a lease clause, an owner's design standard, a certification credit — and answers the question that comes before every other one: does this apply to this project at all. Works the six tests that decide it: is the document adopted or binding here, does the project fall inside its stated scope, has the trigger been met, does an exemption remove it, is this the edition that binds, and is something else more restrictive. Trigger on "does this apply to us", "is this section relevant", "do we have to comply with this", "they say this applies", "applicability-check", or a requirement quoted at you. Carries no text and no thresholds: every answer comes from the document you supply or the jurisdiction's own source. It does not interpret the requirement — `code-reader` takes it apart — and does not replace the code consultant or the Architect of Record.

Applicability Check

Everybody reads what a requirement demands. Almost nobody first checks whether it demands it of them. The wasted work runs in both directions: designing to a requirement that never applied, and being surprised by one whose trigger was met two revisions ago.

Scope and limits — read first

What this does. Runs six tests on a requirement to establish whether it applies to this project, and reports which of the six could be answered and which could not.

What this does not do.

  • It carries no text, thresholds or exemptions. Every answer comes from the document you supply or from the jurisdiction's own published source, never from recall.
  • It does not interpret the requirement or take it apart. code-reader does that, and it runs after this: there is no point taking apart a requirement that does not apply.
  • It does not verify the citation. cite-check does.
  • It does not check the design against it. compliance-check does.
  • It does not find the exception that helps. That is a different question and it is asked after this one concludes the requirement does apply.
  • It does not replace the code consultant or the Architect of Record.

What you need before starting. The requirement, quoted, including its scope statement and its exemptions. Who says it applies, and where they say it. The project's own facts: use, size, height, storeys, construction type, jurisdiction, whether existing or new.

Workflow

Step 1. Establish who says it applies

Ask, in one message:

  1. The requirement, quoted, with its scope and exemption clauses.
  2. Who says it applies? A reviewer, a consultant, a contractor, a manufacturer, a specification, or your own assumption?
  3. Where did they say it: a letter, a report, a spec section, a conversation?
  4. What jurisdiction, and what is the project: use, size, height, storeys, construction type, new or existing?
  5. What is riding on the answer?

Question 2 matters. A reviewer saying it applies is close to the end of the conversation. A manufacturer saying so is a sales position. Your own assumption is the one worth checking hardest, because nobody will.

Step 2. Run the six tests

#TestAnswerSource
1Is the document adopted or binding here at all?
2Does the project fall inside its stated scope?
3Has the trigger been met?
4Does an exemption remove it?
5Is this the edition that binds?
6Is something else more restrictive?

1. Adopted or binding. A code is adopted by a jurisdiction. A standard binds because a code adopts it or a specification names it. A guideline binds nothing on its own. Point at standard-reader.

2. Scope. Every requirement has a scope statement and it is usually one sentence at the top of the section that nobody reads. Quote it and set the project against it.

3. Trigger. Many requirements apply only above a threshold or after an event: an area, a height, an occupant load, a change of use, an alteration exceeding some proportion. Say what the trigger is and whether it is met, and say when the answer would change.

4. Exemption. The paragraph after the requirement. Exemptions are where the answer most often flips and where reading stops one sentence too early.

5. Edition. The edition that binds is the adopted or specified one, not the current one. Point at cite-check.

6. More restrictive. Where two documents both apply, the stricter usually governs, and answering only about this one is half an answer.

Step 3. Report each test separately

Never a single yes or no. Three outcomes per test: yes, no, and cannot answer from what was supplied, which is the honest one and is common.

If any of tests 1 to 4 is a clear no, say so plainly and stop the analysis there — but still report the tests you could not run, because a no resting on an unread scope statement is not a no.

Step 4. Say what would settle it

For every test that could not be answered:

  • What document would answer it.
  • Who has it.
  • Whether the authority should simply be asked, which is often faster than any of the above and is the answer people avoid. Point at permit-expeditor.

Where the answer is genuinely arguable, say so. Applicability is argued in front of authorities all the time, and a question with a real argument on both sides should be flagged as one rather than resolved here.

Step 5. Report

  • Who says it applies, and what standing that has.
  • The six tests, each answered separately with its source.
  • The conclusion: applies, does not apply, or cannot be determined — and never a conclusion that rests on a test nobody ran.
  • What would settle the open tests.
  • If it applies: point at code-reader to take it apart and at compliance-check to hold the design against it.

Step 6. Save, if asked

Ask whether to write the check to a file and where. Point at jurisdiction-profile, where a settled applicability question belongs so it is answered once.

Rules

  • Ask who says it applies, before anything else.
  • Run all six tests and report each separately.
  • Never conclude from a test nobody ran. cannot answer is a result.
  • Quote the scope statement and the exemption; never summarise them.
  • Check the edition that binds, not the current one.
  • Ask whether something else is more restrictive.
  • Say when the answer is genuinely arguable rather than resolving it.

Anti-patterns

  • Reading what a requirement demands before asking whether it demands it of you.
  • Accepting a manufacturer's or a contractor's word that something applies.
  • Reading the requirement and stopping before the exemption.
  • Answering about one document when two apply.
  • Assuming the current edition binds.
  • Producing a single yes or no.
  • Concluding it does not apply because the trigger was not met, without reading the scope.

Resources

None. This skill is one file. Output is written directly at the path you choose.

finishing-a-development-branchobra/superpowersUse when implementation is complete, all tests pass, and you need to decide how to integrate the workStars: 322kUpdated Claude CodeCodexVerifiedInstall
systematic-debuggingobra/superpowersUse when encountering any bug, test failure, or unexpected behavior, before proposing fixesStars: 322kUpdated Claude CodeCodexVerifiedInstall
test-driven-developmentobra/superpowersUse when implementing any feature or bugfix, before writing implementation codeStars: 322kUpdated Claude CodeCodexVerifiedInstall
skill-creatoranthropics/skillsCreate new skills, modify and improve existing skills, and measure skill performance. Use when users want to create a skill from scratch, edit, or optimize an existing skill, run evals to test a skill, benchmark skill performance with variance analysis, or optimize a skill's description for better triggering accuracy.Stars: 198kUpdated Claude CodeCodexVerifiedInstall