Use when you must compute the rayleigh-flow state change of a perfect gas heated or cooled in a constant-area frictionless duct: convert the inlet Mach number into the Rayleigh-line ratios against the sonic state T/T*, p/p*, rho/rho*, T0/T0*, p0/p0*; find the maximum heat addition that thermally chokes the duct from a subsonic or supersonic inlet Mach number, q_max = cp*T1*(1 - M^2)^2/(2*(gamma+1)*M^2); recover the exit Mach number after a given heat addition per unit mass on the inlet branch; and report the entropy rise from the second law. Produces the station ratio set, the choking heat addition, the exit Mach and stagnation pressure ratio, and the entropy rise, in SI units, that gate the heat-addition duct assessment. Trigger: heat addition duct, thermal choking, rayleigh flow, rayleigh line, constant area frictionless duct.

Rayleigh Flow (aerodynamics/high-speed/rayleigh-flow)

Use when you must compute the state change of a perfect gas heated or cooled in a constant-area frictionless duct, the Rayleigh flow that closes the pair with the Fanno friction duct of the same wave. This leaf implements the closed-form Rayleigh-line station relations against the thermal-choking sonic state (the star state of the same-mass-flow duct, reached at M = 1), the maximum heat addition that thermally chokes the duct on either inlet branch, the exit Mach number after a prescribed heat addition recovered from the quadratic total-temperature balance, and the second-law entropy rise, in pure Python stdlib. It pairs with the same-pack isentropic-flow-relations (frictionless duct WITHOUT heat: total temperature frozen, isentropic throat A*) and the same-pack fanno-flow (adiabatic duct WITH wall friction) as the two non-isentropic constant-area duct mechanisms of the wave; heat in, no friction here.

Domain quick reference

Air at gamma = 1.4, R = 287.0 J/(kg K), cp = gammaR/(gamma - 1) = 1004.5 J/(kg K), constant specific heat only. The star denotes the state of the same-mass-flow constant-area frictionless duct at M = 1, i.e. thermal choking, and f = 1 + gammaM^2:

  • Static ratios: T/T* = M^2*(1+gamma)^2/f^2, p/p* = (1+gamma)/f, rho/rho* = f/(M^2*(1+gamma)) = (p/p*)/(T/T*) exactly. T/T* peaks at (1+gamma)^2/(4*gamma) = 36/35 = 1.02857142857 at M = 1/sqrt(gamma).
  • Total ratios: T0/T0* = (T/T*)(1 + (gamma-1)M^2/2)2/(gamma+1); p0/p0 = (p/p)((1 + (gamma-1)*M^2/2)*2/(gamma+1))^(gamma/(gamma-1)). All five ratios equal 1 at M = 1.
  • Heat balance: T0_2 = T0_1 + q/cp, so T0_2/T0_1 = 1 + q/(cpT0_1); T0 of the duct is fixed, so every state ratio between two stations of one duct is the ratio of the station Rayleigh ratios at their Mach numbers.
  • Thermal choking: q_max = cpT1(1 - M1^2)^2/(2*(gamma+1)M1^2) = cp(T0* - T0_1), zero at M1 = 1 and symmetric under M1 to 1/M1 at equal static temperature (a Mach 0.5 inlet and a Mach 2.0 inlet at the same T1 choke on the same heat per kilogram).
  • Exit Mach: with g(M) = T0/T0*(M), g2 = g(M1)(1 + q/(cpT0_1)), and g(M2) = g2 is a quadratic in x = M2^2 solved by the quadratic formula: (gamma^2 - 1 - g2gamma^2)x^2 + (2(1+gamma) - 2g2*gamma)*x - g2 = 0. Subsonic inlet: smaller positive root, M2 in (0, 1]. Supersonic inlet: larger positive root, M2 in [1, inf), which exists only above the branch floor g2 = (gamma^2 - 1)/gamma^2 reached asymptotically as M goes to infinity.
  • Entropy: ds = cpln(T2/T1) - Rln(p2/p1); on the T-s plane the Rayleigh curve offset (s - s*)/cp = ln(T/T*) - ((gamma-1)/gamma)* ln(p/p*) is strictly negative off M = 1 and zero at M = 1, the entropy maximum of the Rayleigh line. Heat addition always raises the stagnation temperature and always lowers the stagnation pressure ratio p0_2/p0_1 = p0/p0*(M2)/p0/p0*(M1) below 1 (0.8976 at thermal choke from a Mach 0.5 inlet).
  • Units SI throughout: Pa, K, kg/m3, J/kg, J/(kg K).

Workflow

  1. Fix the duct inlet state: static temperature t_static (K), static pressure p_static (Pa), inlet Mach number mach, and the heat addition per unit mass q in J/kg (positive heats, negative rejects).
  2. Convert the inlet Mach number into the five Rayleigh-line station ratios with rayleigh_ratios; every ratio equals 1 at the thermal-choking sonic state M = 1.
  3. Find the maximum heat addition that thermally chokes the duct with heat_addition_maximum: q_max in J/kg from the static-temperature closed form, valid on both branches and symmetric under mach to 1/mach.
  4. Recover the exit Mach number after the given heat addition on the inlet's own branch with exit_mach: smaller positive root for a subsonic inlet, larger positive root for a supersonic inlet; q at q_max returns 1.0 (thermally choked), q above q_max and supersonic rejection past the branch floor raise ValueError.
  5. Build the downstream station with heat_addition: the absolute exit state (m2, t2, p2, rho2, t02, p02), the station ratios t2_over_t1, p2_over_p1, rho2_over_rho1, t02_over_t01, p02_over_p01, the second-law entropy rise ds and ds_over_cp, and the choked flag; entropy_rise gives ds between any two gas states.
  6. Check the Rayleigh T-s curve offset identity with rayleigh_curve_offset: ds/cp between two stations of one duct equals the curve-offset difference at their Mach numbers, and the sonic point M = 1 is the entropy maximum of the Rayleigh line.
  7. Confirm the deterministic contract with the offline test scripts/test_rayleigh_flow.py.

Worked example

Air at T1 = 300 K, p1 = 101325 Pa, run at the dual inlet pair M1 = 0.5 (subsonic branch) and M1 = 2.0 (supersonic branch). Real module outputs:

  • Station ratios at the inlet: M1 = 0.5 gives T/T* = 0.790123456790, p/p* = 1.777777777778, rho/rho* = 2.25, T0/T0* = 0.691358024691, p0/p0* = 1.11405250318, with T0_1 = 315.000 K and T0* = 455.625 K; M1 = 2.0 gives 0.528925619835, 0.363636363636, 0.6875, 0.793388429752, 1.50309597853, with T0_1 = 540.000 K and T0* = 680.625 K.
  • Maximum heat addition: q_max = heat_addition_maximum(300, 0.5) = heat_addition_maximum(300, 2.0) = 141257.8125 J/kg in both cases (141.3 kJ/kg chokes either duct): q_max/(cpT1) = 0.46875, and q_max = cp(T0* - T0_1) = cp*140.625 J/kg on both branches.
  • Subsonic inlet M1 = 0.5, q = q_max/2 = 70628.90625 J/kg: heat_addition gives exit M2 = 0.625879453912 (heating accelerates the subsonic flow toward 1), T2 = 357.318 K, p2 = 88341.135 Pa, T2/T1 = 1.19106128221, p2/p1 = 0.871859216769, rho2/rho1 = 0.732001979908, T0_2/T0_1 = 1.22321428571 (stagnation temperature rises 22.3%), p0_2/p0_1 = 0.957052789099 (stagnation pressure falls 4.3%), ds = 214.987 J/(kg K), ds/cp = 0.214023976827.
  • At q = q_max the exit reaches M2 = 1 exactly with p0_2/p0_1 = 0.897623762925 = 1/1.11405250318, the minimum stagnation pressure ratio the heating duct can deliver.
  • Supersonic inlet M1 = 2.0, same q = 70628.90625 J/kg: exit M2 = 1.54998945381 (heating decelerates the supersonic flow toward 1), T2 = 412.236 K, p2 = 153260.459 Pa, T2/T1 = 1.37411954397, p2/p1 = 1.51256313292, rho2/rho1 = 1.10075076042, T0_2/T0_1 = 1.13020833333, p0_2/p0_1 = 0.763277518128 (the same heat costs 23.7% of the stagnation pressure), ds = 200.481 J/(kg K).
  • Heat rejection: q = -50000 J/kg at M1 = 0.5 drives the exit to M2 = 0.430803500026 with ds/cp = -0.17940496639 (cooling lowers entropy); q = -200000 J/kg at M1 = 2.0 accelerates the exit to M2 = 12.5126628564; rejection past the supersonic branch floor (roughly -207.6 kJ/kg here) has no steady Rayleigh state and raises.
  • Read-off: adding 70.6 kJ/kg to the Mach 0.5 duct accelerates it to M 0.626 with a 4.3% stagnation pressure loss and ds = 215 J/(kg K); the identical heat input to the Mach 2 duct decelerates it to M 1.55 with a 23.7% loss and ds = 200 J/(kg K).

Verification

  • rayleigh_ratios(0.5) returns the five ratios above; rayleigh_ratios(2.0) the supersonic set; all five ratios return 1 within 1e-12 at M = 1.
  • rho/rho* equals (p/p*)/(T/T*) within 1e-12 at M = 0.5 and M = 2.
  • heat_addition_maximum(300, 0.5) equals heat_addition_maximum(300, 2.0) = 141257.8125 J/kg within 1e-12 relative (the M to 1/M duality), equals cp*(T0* - T0_1) within 1e-12, and is 0 within 1e-15 at M = 1.
  • exit_mach chokes at the module q_max (exit 1.0 within 1e-9) and the half-choke exits match the worked example within 1e-9 relative.
  • ds equals cpln(T2/T1) - Rln(p2/p1) within 1e-9 and ds/cp equals rayleigh_curve_offset(m2) - rayleigh_curve_offset(m1) within 1e-12.
  • Rejection gives ds < 0; q above q_max raises ValueError naming the thermal choking limit; supersonic rejection past the branch floor raises ValueError naming the branch limit; q at or below -cp*T0_1 on a subsonic inlet raises; non-positive mach, temperature, pressure and density-driving inputs raise ValueError across the module.
  • Run the contract test offline: python3 scripts/test_rayleigh_flow.py (32 tests, deterministic, identical under both interpreters).

Contract test

Run the deterministic contract test (stdlib unittest, offline):

python3 scripts/test_rayleigh_flow.py

The test covers the published gamma-1.4 Rayleigh table agreement at M = 0.5 and M = 2.0 (fractional values 64/81, 16/9, 9/4, 56/81 and 64/121, 4/11, 11/16, 96/121), unity of all five ratios at the sonic state, the density round trip, the T/T* peak 36/35 at M = 1/sqrt(gamma), the q_max closed form with its M to 1/M duality and the cp*(T0* - T0_1) equivalence, thermal choking at the module q_max on both branches, the subsonic and supersonic half-choke exit states with the full downstream ratio and entropy set, the second-law entropy identity, the Rayleigh curve-offset identity, heat rejection on both branches, and ValueError rejection of every non-physical input class.

Related leaves

  • aerodynamics/high-speed/isentropic-flow-relations: the frictionless ADIABATIC complement (total temperature frozen across the duct, the isentropic throat A*), for the no-heat conversion of Mach number into total to static ratios and choked mass flow.
  • aerodynamics/high-speed/fanno-flow: the adiabatic constant-area duct WITH wall friction (Fanno line, choking length), the complementary non-isentropic constant-area duct mechanism to this leaf.
  • propulsion/gas-turbine-cycle/combustor-design: the burner thermochemistry that produces the heat addition from fuel flow, the upstream source of q for a real heat-addition duct.
  • aerodynamics/high-speed/hypersonic-flow: the Rayleigh pitot relation for stagnation pressure behind a normal or bow shock, a shock relation distinct from this Rayleigh flow duct model.

Pitfalls

  • Using the isentropic throat for the heated duct: with heat addition the total temperature changes, T0_2 = T0_1 + q/cp, and the sonic state is the thermal-choking state of the same-mass-flow duct (a different star), not the isentropic area throat A*.
  • Adding heat at the sonic point: a duct already at M = 1 is thermally choked; any further heat addition has no steady Rayleigh state, and the module raises rather than returning a spurious exit.
  • Rejecting heat past the supersonic branch floor: the balance g2 = g(M1)(1 + q/(cpT0_1)) falls below (gamma^2 - 1)/gamma^2 only when the exit would exceed infinite Mach, so the branch limit raises; q = -cp*T0_1 on the subsonic side is the mirror limit as M2 tends to 0.
  • Reading the exit Mach off the wrong branch root: the balance quadratic has a root on each branch, the subsonic inlet takes the smaller positive root and the supersonic inlet the larger one; mixing the branches returns a Mach number on the wrong side of 1.
  • Treating heat addition as always raising the static temperature: static temperature rises only up to M = 1/sqrt(gamma), where T/T* peaks at 36/35; heating a supersonic duct raises its static temperature and pressure while its Mach number falls toward 1.
  • Quoting the entropy change sign from the Mach drift alone: ds is negative under heat rejection even though rejection accelerates a supersonic flow, and ds/cp is always the curve-offset difference ln(T/T*) - ((gamma-1)/gamma)ln(p/p) between the two stations.

Behavior contract (gate 3)

Run the deterministic contract test (stdlib unittest, offline):

python3 scripts/test_rayleigh_flow.py

The test exercises the five Rayleigh-line station ratios, the thermal-choking heat addition with the M to 1/M duality, the exit Mach recovery on each inlet branch, the full downstream state with stagnation temperature rise and stagnation pressure fall, the second-law entropy rise, the T-s curve offset identity, heat rejection, and ValueError rejection of non-physical inputs.

Compliance

  • Standards referenced, not reproduced: NACA-TR-824 frames the one-dimensional compressible-flow methodology; the Rayleigh-line relations above are standard engineering methodology, summary-only per standards-map.yaml (reference-only).
  • compliance: STANDARDS-REF, gated: false.
slack-gif-creatoranthropics/skillsKnowledge and utilities for creating animated GIFs optimized for Slack. Provides constraints, validation tools, and animation concepts. Use when users request animated GIFs for Slack like "make me a GIF of X doing Y for Slack."Stars: 198kUpdated Claude CodeCodexVerifiedInstall
ponytailDietrichGebert/ponytailLazy senior dev mode for any coding task: the smallest change that fully solves it, and a reply a busy human understands in one read.Stars: 194kUpdated Claude CodeCodexVerifiedInstall
ponytail-debtDietrichGebert/ponytailHarvest every shortcut: comment into one debt ledger, so deferrals get tracked instead of forgotten. One-shot report.Stars: 194kUpdated Claude CodeCodexVerifiedInstall
ponytail-debtDietrichGebert/ponytailList every `shortcut:` comment (and older `ponytail:` ones) as a debt ledger. One-shot report, changes nothing. Use for "ponytail debt", "what did ponytail defer", "list the shortcuts", /ponytail-debt.Stars: 194kUpdated Claude CodeCodexVerifiedInstall