Explore skills
Search every indexed skill by name, description, repository or instructions, then narrow the results.
Showing 46351–46380 of 53835 skills
| Skill | Stars | Updated | Works with | Status | Install |
|---|---|---|---|---|---|
| design-beamDavidCho1999/archaiflow-skillsSizes a single simply-supported beam in steel, wood, or reinforced concrete for a known span, tributary load, and deflection limit, showing every step of the arithmetic. Trigger on "size beam", "preliminary beam size", "pick a section", "glulam beam size", "concrete beam size", "beam deflection check", "design-beam", or a pasted span with loads. Works with any design standard. The user names the standard, the design method, and supplies the load combinations, material properties, section properties, resistance factors, and deflection limit, by typing them, pasting the table, or naming a file. The skill never supplies an engineering value from memory or from web search. Preliminary sizing only, for a fully braced simple span, and never a substitute for the Engineer of Record. | Stars: 1 | Updated | Claude CodeCodex | Unverified | Install |
| design-below-grade-assemblyDavidCho1999/archaiflow-skillsBuilds a below-grade wall or slab assembly from the water condition first: takes the groundwater regime, the soil, the structure, how the space below grade will be used and whether the waterproofing can ever be reached again, then places the water, thermal and vapor control layers in an order, gives every layer a job, and works the joints, penetrations and the at-grade transition where below-grade work actually fails. Trigger on "below grade waterproofing", "basement wall build-up", "foundation wall assembly", "slab on grade vapor barrier", "blindside waterproofing", "design-below-grade-assembly", or a foundation wall and a water table named with a request for what goes between them. Supplies the ordering logic and the questions each condition has to answer; supplies no thickness, no permeance, no hydrostatic head, no code requirement and no proprietary product. It does not size drainage, does not do geotechnical or structural work, and does not replace the waterproofing consultant or the Architect of Record. | Stars: 1 | Updated | Claude CodeCodex | Unverified | Install |
| design-ceilingDavidCho1999/archaiflow-skillsWorks the ceiling as the place every discipline's leftovers land: adds up what has to fit in the plenum in the order it gets installed, finds the one crossing that sets the height for the whole floor, and works access, transitions and the elements that arrive late and wreck a reflected ceiling plan. Reports the height available against the height wanted. Trigger on "ceiling height", "what fits in the plenum", "reflected ceiling plan", "will the duct clear the beam", "ceiling access", "design-ceiling", or a floor-to-floor with a question about what it leaves. Carries no depths, no clearances and no code requirements; structural depths come from the engineer, service sizes from the MEP set, and required heights from the code you quote. It does not size services or structure and does not replace the engineers or the Architect of Record. | Stars: 1 | Updated | Claude CodeCodex | Unverified | Install |
| design-columnDavidCho1999/archaiflow-skillsChecks a single axially loaded, braced column against the capacity your standard's values produce, with every step of the arithmetic shown: slenderness from your effective length factor, capacity from the expression or table row you supply, demand over capacity at the end. Trigger on "column check", "column size", "post size", "axial capacity", "slenderness check", "KL/r", "design-column", or a pasted column load with a trial section. Works with any design standard. The user names the standard and method and supplies the load combinations, the effective length factor, the section and material properties, and the capacity expression or its tabulated value, by typing, pasting, or naming a file; the skill never supplies an engineering value, a buckling curve, or a section from memory or web search. Concentric axial load on a braced member only; combined bending needs your interaction equation or it stops. Preliminary sizing, never a substitute for the Engineer of Record. | Stars: 1 | Updated | Claude CodeCodex | Unverified | Install |
| design-coreDavidCho1999/archaiflow-skillsAggregates the pieces of a building core (elevator shafts, stairs, toilets, mechanical and electrical shafts and rooms) from dimensions the user supplies, applies the user's own wall-and-circulation factor, and reports total core area and core-to-floor-plate ratio against the user's benchmark, showing every step. Trigger on "core sizing", "how big is my core", "core-to-floor ratio", "core efficiency", "design-core", or a floor plate paired with a list of core components. Every dimension comes from the user: shaft sizes from manufacturer cut sheets, stair footprints from the user's stair layout, room sizes from the user's plans, the grossing factor and the target ratio from the user's own benchmarks. The skill never supplies a typical shaft size, fixture count, or target ratio. It does not decide elevator count (the elevator consultant's traffic analysis does), does not check stair or fixture code compliance, and is not a substitute for the Architect of Record. | Stars: 1 | Updated | Claude CodeCodex | Unverified | Install |
| design-criticDavidCho1999/archaiflow-skillsThis skill should be used when the user shares an architectural project (concept text, plans, sections, renderings, references) and asks for critique, feedback, or a second opinion. Trigger on 'design critique', 'review this design', 'critique this', 'second opinion', or when context implies the user wants challenge over validation. Generates a structured critique markdown in `docs/reviews/` and appends to the project review index. | Stars: 1 | Updated | Claude CodeCodex | Unverified | Install |
| design-ductDavidCho1999/archaiflow-skillsSizes a duct segment from an airflow and the limits you set: area from the velocity limit you state, rectangular dimensions within your aspect ratio, the equivalent-diameter arithmetic between round and rectangular, and a pressure-drop tally over a run when you supply the loss values, every step shown. Trigger on "duct size", "duct sizing", "duct velocity", "equivalent diameter", "static pressure", "cfm to duct size", "design-duct", or a pasted airflow with a size question. Works in either unit system, as given. The user supplies the airflow, the velocity or friction-rate limit with where it came from, aspect ratio limits, and any fitting loss values, cited; the skill never supplies a velocity limit, a friction rate, or a loss coefficient from memory or from web search. Geometry and arithmetic only: fan selection, system effect, acoustics, and leakage class are the mechanical engineer's calls. Preliminary, never a substitute for the mechanical Engineer of Record. | Stars: 1 | Updated | Claude CodeCodex | Unverified | Install |
| design-egressDavidCho1999/archaiflow-skillsChecks a floor or a tenancy against the means-of-egress items every building code regulates: egress capacity per occupant, number of exits required, single-exit allowance, common path of travel, exit separation, travel distance, corridor width, dead-end length, door clear width, and door swing threshold. Trigger on "check egress", "egress review", "exit count", "travel distance", "common path", "exit separation", "dead end corridor", "design-egress", "IBC 1006", "IBC 1017", "OBC 3.4", or a pasted plan with occupant load and exit positions. Works in any jurisdiction. The user names the governing code and edition and supplies each limit by typing it, pasting the clause, or naming a file to read. The skill never supplies a limit from memory or from web search, and any item without a supplied limit is reported as unverified rather than assumed. Does not compute occupant load, and does not replace the Architect of Record or the AHJ. | Stars: 1 | Updated | Claude CodeCodex | Unverified | Install |
| design-electrical-roomDavidCho1999/archaiflow-skillsLays out an electrical, communications or service entrance room around the working clearances that surround the equipment rather than around the equipment itself, because those clearances are code, they are volumes, and they appear on no architectural drawing by default. Works the utility's own requirements separately from the code's, since a service entrance room is designed to the utility's standard and they will refuse a room that meets the code and not their manual. Trigger on "electrical room layout", "how big does the switchgear room need to be", "working clearance in front of the panel", "service entrance room", "transformer vault", "design-electrical-room", or an electrical equipment schedule with a room to put it in. Carries no clearance dimensions, no equipment sizes and no utility requirements. It does not do electrical design and does not replace the electrical engineer or the Architect of Record. | Stars: 1 | Updated | Claude CodeCodex | Unverified | Install |
| design-elevatorDavidCho1999/archaiflow-skillsHolds the architectural space an elevator installation needs from the consultant's or manufacturer's data: the hoistway, the pit below the lowest landing, the overrun above the highest, the machine and controller wherever the product puts them, and the lobby and door dimensions at every level. Works the constraints that decide the building — what the pit does to the foundation, what the overrun does to the roof or the height limit, and where the machine has to be if there is no machine room. Trigger on "elevator pit depth", "lift overrun", "machine room-less", "how big is the hoistway", "elevator shaft coordination", "design-elevator", or an elevator specification handed over to fit into a building. Carries no dimensions, no capacities, no speeds and no code requirements; every one comes from the manufacturer, the elevator consultant, or the code you quote. It does not do traffic analysis and does not replace the elevator consultant or the Architect of Record. | Stars: 1 | Updated | Claude CodeCodex | Unverified | Install |
| design-entryDavidCho1999/archaiflow-skillsWorks the entrance as a continuous sequence rather than as a door: how it is found from the street, what happens on the way in, what the threshold has to hold at once, and where somebody stands when they arrive and nobody is expecting them. Names the four things that meet at a doorway and cannot all be optimised — level access, weather, energy, and security — and says which one this project lets win. Trigger on "entrance design", "the entry sequence", "where is the front door", "vestibule", "the entrance is hard to find", "design-entry", or an entrance that is a door on a plan and nothing more. Carries no dimensions, no threshold limits and no requirements; accessible thresholds and vestibule requirements are code and standards you quote. It does not replace the Architect of Record. | Stars: 1 | Updated | Claude CodeCodex | Unverified | Install |
| design-envelopeDavidCho1999/archaiflow-skillsThe door into envelope work, and the step usually skipped: before any assembly is built up, decide how many envelope types the building actually has, which face gets which, where the junctions between them fall, and what each one has to achieve. Produces the schedule of types and junctions that the assembly and junction skills then execute against, and hands each part off by name. Trigger on "design the envelope", "how many wall types do we need", "what should this facade be", "envelope strategy", "where do the assemblies change", "design-envelope", or an envelope scope with no strategy behind it. Carries no R-values, no assemblies and no code minimums; performance requirements come from the code and the brief you quote. It builds nothing itself — `design-wall-assembly`, `design-roof-assembly` and the junction skills do — and does not replace the enclosure consultant or the Architect of Record. | Stars: 1 | Updated | Claude CodeCodex | Unverified | Install |
| design-expansion-jointDavidCho1999/archaiflow-skillsWorks movement in the enclosure as two questions rather than one: where the joints have to be, given the movements you can name and where they accumulate, and then how each of the four control layers (water, air, vapor, thermal) crosses a gap that opens and closes for the life of the building. Trigger on "expansion joint", "movement joint", "control joint", "where do the joints go", "building separation joint", "how does the air barrier cross a joint", "design-expansion-joint", or a long facade or a structural break named with a request for how the enclosure handles movement. Supplies the reasoning about movement sources, accumulation and joint hierarchy, and the questions each crossing has to answer; supplies no joint spacing, no movement coefficient, no joint width, no code requirement and no proprietary product. It does no structural or thermal calculation and does not replace the enclosure consultant or the Architect of Record. | Stars: 1 | Updated | Claude CodeCodex | Unverified | Install |
| design-fire-barrierDavidCho1999/archaiflow-skillsFollows one rated assembly as a continuous surface rather than as a wall type on a plan: establishes what kind of separation it is and therefore what continuity the code demands, traces it from floor slab to deck above and along its full length, and works every place the rating is interrupted by a penetration, a joint, a duct, a door, a glazed opening or the structure it is attached to. Trigger on "fire barrier detail", "rated wall continuity", "does this wall go to deck", "firestopping at the top of wall", "fire partition versus fire barrier", "rated assembly penetrations", "design-fire-barrier", or a rated wall named with a question about how it is built. Carries no hourly ratings, no opening limits, no tested assembly numbers and no firestop listings; the required rating comes from `/test-fire-rating` or your code analysis, and every assembly and firestop is a tested and listed system you cite. It does not replace the fire protection engineer, the code consultant, or the Architect of Record. | Stars: 1 | Updated | Claude CodeCodex | Unverified | Install |
| design-footingDavidCho1999/archaiflow-skillsChecks a single isolated spread footing: bearing pressure under your loads against the allowable bearing value your geotechnical report gives, with every step of the arithmetic shown. Trigger on "footing size", "spread footing", "bearing pressure", "bearing check", "pad footing", "footing check", "design-footing", or a pasted column load with a bearing value. Works with any standard. The user supplies the loads, the allowable or factored bearing resistance with its source, the load combinations, and a trial plan size; the skill never supplies a bearing value, a soil property, or a frost depth from memory or from web search. Plan size and bearing only: the footing's thickness, shear, and reinforcement are concrete design and stop the run. Preliminary sizing, never a substitute for the Engineer of Record or the geotechnical engineer. | Stars: 1 | Updated | Claude CodeCodex | Unverified | Install |
| design-interiorDavidCho1999/archaiflow-skillsThe door into interior work, and the step that is usually missing: before partitions, ceilings, millwork or finishes are drawn, establish what each space actually has to withstand, where the money should go, which spaces repeat and which get attention, and what the base building has already decided. Produces the strategy the specific skills then execute against, and hands each part off by name. Trigger on "design the interior", "interior strategy", "where do we spend on this fit-out", "what finishes for this project", "the interior feels arbitrary", "design-interior", or an interior scope with no strategy behind it. Carries no finishes, no specifications, no costs and no ratings; every requirement comes from the brief, the client's operation, or the code you quote. It details nothing itself — `design-partition`, `design-ceiling`, `design-millwork` and `schedule-builder` do that — and does not replace the interior designer or the Architect of Record. | Stars: 1 | Updated | Claude CodeCodex | Unverified | Install |
| design-kitchenDavidCho1999/archaiflow-skillsLays out a domestic or small commercial kitchen from the sequence of work rather than from a triangle: where things arrive, where they are stored, prepared, cooked, served and cleaned, and what has to be within reach of what. Then works the two things that decide whether the layout survives — where the services can actually go, and what the ventilation demands of the plan and the elevation. Trigger on "kitchen layout", "design the kitchen", "galley or island", "where does the hood vent", "kitchen work triangle", "design-kitchen", or a kitchen with appliances chosen and nowhere settled. Carries no clearances, no aisle widths, no appliance dimensions and no ventilation rates; each comes from the code you quote, the accessibility standard, or the appliance's own data. Commercial kitchens beyond a small back-of-house are a specialist consultant's. It does not replace the Architect of Record. | Stars: 1 | Updated | Claude CodeCodex | Unverified | Install |
| design-mechanical-roomDavidCho1999/archaiflow-skillsLays out a mechanical plant room from the equipment schedule the engineer gives you, and adds the four things that make it bigger than the equipment: the service clearances each unit needs, the route to get equipment in during construction and out at replacement, the air the room itself has to take in and exhaust, and the connections that leave it. Reports the required footprint and height against what is drawn. Trigger on "size the mechanical room", "plant room layout", "will the AHU fit", "how do we get the chiller in", "mechanical room design", "design-mechanical-room", or an equipment schedule handed over with a room to put it in. Carries no equipment dimensions, no clearances, no ventilation rates and no code requirements; all come from the engineer, the manufacturer and the code text you quote. It does not select or size equipment and does not replace the MEP engineer or the Architect of Record. | Stars: 1 | Updated | Claude CodeCodex | Unverified | Install |
| design-millworkDavidCho1999/archaiflow-skillsDetails built-in joinery to the point a shop can price it without asking: what is fixed and what moves, how it meets a floor and a wall that are neither level nor straight, what it hangs off and whether that backing exists, where the services in it come from, and which decisions are the shop's rather than the drawing's. Trigger on "millwork", "casework", "joinery detail", "built-in", "reception desk", "how does this cabinet meet the wall", "design-millwork", or a built-in element that has to be drawn for tender. Carries no dimensions, no clearances, no material thicknesses and no hardware; ergonomic and accessible dimensions come from the standard you quote and every material figure from the fabricator or the data sheet. It is not shop drawing — `submittal-review` reads those when they come back — and does not replace the Architect of Record. | Stars: 1 | Updated | Claude CodeCodex | Unverified | Install |
| design-narrativeDavidCho1999/archaiflow-skillsWrites the project description that gets asked for again and again in different lengths and for different readers: a planning submission, a design review board, an award entry, a website page, a client's own report. Establishes who is reading and what they can do about it before writing a word, since a board that can refuse and a magazine that cannot are different documents, then builds one account of the project that the shorter versions are cut from rather than rewritten. Trigger on "design narrative", "project description", "write up the project", "we need a paragraph for the submission", "award entry text", "design-narrative", or a request for words about a building. Carries no house voice and no claims of its own; every fact comes from the project and every claim has to be true of the drawings. It does not replace the Architect of Record. | Stars: 1 | Updated | Claude CodeCodex | Unverified | Install |
| design-occupancy-loadDavidCho1999/archaiflow-skillsComputes occupant load space by space, then subtotals by use group and gives a building or floor total. Trigger on "occupant load", "calc occupants", "occupancy load", "how many occupants", "design-occupancy-load", "IBC 1004", "OBC 3.1.17", or a pasted program listing spaces with use and area. A foundation calculation: its output feeds egress, plumbing fixture counts, allowable area, and stair width. Works in any jurisdiction. The user names the governing code and edition and supplies each load factor by typing it, pasting the table row, or naming a file to read. The skill never supplies a factor from memory or from web search, and a space with no factor is reported as unverified rather than estimated. Does not count fixed seating, and does not replace the Architect of Record or the AHJ. | Stars: 1 | Updated | Claude CodeCodex | Unverified | Install |
| design-panel-loadDavidCho1999/archaiflow-skillsTotals an electrical panel or service load: connected load summed by the categories your code uses, demand factors applied as you cite them, continuous-load multipliers as you cite them, and the result converted to amps at the voltage you state, with every step of the arithmetic shown. Trigger on "panel load", "load calc", "service size", "connected load", "demand load", "panel schedule totals", "design-panel-load", or a pasted load list. Works with any electrical code. The user supplies the load list, the category rules, the demand factor rows, and any multipliers, pasted and cited; the skill never supplies a demand factor, a VA allowance, or a multiplier from memory or from web search, and categories without a cited factor come out at connected load, marked unverified. Load totalling only: conductor and breaker sizing, fault current, voltage drop, and coordination are the electrical engineer's calculations and stop the run. | Stars: 1 | Updated | Claude CodeCodex | Unverified | Install |
| design-parapetDavidCho1999/archaiflow-skillsWorks a parapet as the junction of two assemblies rather than as a wall that continues past the roof: takes the wall build-up and the roof build-up you already have, then carries each of the four control layers (water, air, vapor, thermal) up the inside face, over the top and down the outside, naming where each one transfers from one assembly to the other and what happens at the coping, the through-wall flashing, the corners and every interruption. Trigger on "design a parapet", "parapet detail", "coping", "where does the air barrier turn at the roof", "through-wall flashing at the parapet", "parapet thermal bridge", "design-parapet", or a wall and a roof named with a request for how they meet at the top. Supplies the ordering and transfer logic and the questions each condition has to answer; supplies no height, no thickness, no slope, no code requirement and no proprietary product. Requires the two assemblies as input and does not design either of them. | Stars: 1 | Updated | Claude CodeCodex | Unverified | Install |
| design-parking-layoutDavidCho1999/archaiflow-skillsLays out a parking floor from the module rather than from the space left over: settles the bay and aisle dimensions and the column grid that follows from them, works the ramp against the floor-to-floor it has to climb, places accessible spaces where the standard requires them rather than where they fit, and reports the count achieved against the count required. Trigger on "parking layout", "how many cars fit", "parking bay module", "ramp slope and transitions", "where do the accessible spaces go", "design-parking-layout", or a garage floor plate with a count to hit. Carries no bay dimensions, no aisle widths, no ramp slopes, no headroom and no accessible ratios; every one comes from the jurisdiction's standard or the accessibility standard you quote. `/test-parking` counts what is required. It does not do traffic or structural engineering and does not replace the Architect of Record. | Stars: 1 | Updated | Claude CodeCodex | Unverified | Install |
| design-partitionDavidCho1999/archaiflow-skillsBuilds an interior partition type from what the partition has to do rather than from a wall type legend copied forward: takes the acoustic separation, the fire rating, the structural condition above and what has to be fixed to it, then works the build-up and the two decisions that decide whether it performs — how far up it goes, and what happens at the head where the structure above moves. Trigger on "partition type", "interior wall build-up", "does this wall go to deck", "STC between these rooms", "deflection head detail", "wall type legend", "design-partition", or a room adjacency with a question about the wall between. Carries no ratings, no STC values, no stud spacings and no listings; performance comes from the specification or the acoustician and every rated assembly is a tested system you cite. For an exterior wall use `design-wall-assembly`; for a rated assembly's continuity use `design-fire-barrier`. It does not replace the Architect of Record. | Stars: 1 | Updated | Claude CodeCodex | Unverified | Install |
| design-roof-assemblyDavidCho1999/archaiflow-skillsBuilds a low-slope or steep-slope roof assembly from what the roof has to do rather than from a remembered stack: takes the membrane or covering, the deck, the climate, the interior humidity, the equipment landing on it and the slope you have to work with, then places the four control layers (water, air, vapor, thermal) in an order, gives every layer a stated job, and works the curbs, drains, penetrations and edges where roofs actually leak. Trigger on "design a roof assembly", "roof build-up", "compact roof", "what goes above the deck", "insulation above or below the deck", "vented or unvented roof", "design-roof-assembly", or a membrane and a deck named with a request for what sits between them. Supplies the ordering logic and the questions each condition has to answer; supplies no R-value, no permeance, no slope minimum, no code requirement and no proprietary product. The arithmetic belongs to condensation-check and the continuity audit to air-barrier-trace, both of which this hands off to. | Stars: 1 | Updated | Claude CodeCodex | Unverified | Install |
| design-roof-drainageDavidCho1999/archaiflow-skillsWorks roof drainage as the architectural half of a problem the plumbing engineer sizes: where the falls come from and what they cost the build-up, where the drains land against the structure and the spaces below, where the secondary drainage goes and whether anyone would notice it running, and what the roof weighs if the primary drains block. Trigger on "roof drainage", "where do the drains go", "tapered insulation layout", "overflow scuppers", "is the roof ponding", "design-roof-drainage", or a roof plan with a question about falls. Carries no drain sizes, no rainfall intensities, no slope minimums and no code requirements; sizing is the plumbing engineer's against the code you quote, and the ponding load is the structural engineer's. `design-roof-assembly` builds the stack and names this as out of its scope. It does not replace the engineers or the Architect of Record. | Stars: 1 | Updated | Claude CodeCodex | Unverified | Install |
| design-stairDavidCho1999/archaiflow-skillsChecks one stair flight item by item: width, headroom, riser, tread, uniformity, nosing, landing, vertical rise between landings, handrail height, wall clearance, cross section, extensions, both-sides requirement, and open risers. Trigger on "check stair", "stair compliance", "stair dimension check", "riser tread check", "handrail extension", "stair code check", "IBC 1011", "ADA stair", "OBC stair", "NBC stair", or pasted stair geometry. Works in any jurisdiction. The user names the governing code and edition, then supplies each limit by typing it, pasting the clause, or naming a file to read. The skill never supplies a code value from memory or from web search, and any row without a supplied limit is reported as unverified rather than guessed. Does not replace the Architect or Engineer of Record, and does not cover curved, spiral, winder, or alternating tread stairs. | Stars: 1 | Updated | Claude CodeCodex | Unverified | Install |
| design-ventilationDavidCho1999/archaiflow-skillsComputes outdoor-air ventilation rates zone by zone from the rate table you paste, with every step of the arithmetic shown: people component plus area component per zone, adjusted and summed the way your standard's procedure says. Trigger on "ventilation rate", "outdoor air", "OA calculation", "cfm per person", "air changes", "ventilation calc", "design-ventilation", or a pasted room schedule with occupancies. Works with any ventilation standard. The user names the standard and pastes its rate rows, occupant counts or the density rule, areas, and any effectiveness or system-level factors, each cited; the skill never supplies a rate, a density, or a factor from memory or from web search, and rows without a supplied rate come out unverified rather than filled. Supply-side outdoor air only: exhaust requirements, duct sizing, and energy are other calculations. Preliminary, never a substitute for the mechanical Engineer of Record. | Stars: 1 | Updated | Claude CodeCodex | Unverified | Install |
| design-wall-assemblyDavidCho1999/archaiflow-skillsBuilds an exterior wall assembly from what the wall has to do rather than from a remembered stack: takes the cladding, the structure, the climate, the fire and acoustic demands and the drying direction you state, then places the four control layers (water, air, vapor, thermal) in an order, gives every layer a stated job, and works each interface where two layers meet and each transition where the wall stops. Trigger on "design a wall assembly", "wall build-up", "what goes in this wall", "layer the exterior wall", "where does the air barrier go", "rainscreen build-up", "design-wall-assembly", or a cladding and a structure named with a request for what sits between them. Supplies the ordering logic and the questions each interface has to answer; supplies no R-value, no permeance, no code minimum and no proprietary product. The arithmetic on the finished stack belongs to condensation-check and the continuity audit to air-barrier-trace, both of which this hands off to. | Stars: 1 | Updated | Claude CodeCodex | Unverified | Install |