VerifiedMATLAB and Simulink workflow for creating, inspecting, modifying, simulating, validating, and exporting .slx models. Use for Simulink, Stateflow, Simscape, model-based design, parameter sweeps, signal logging, requirements, and simulation automation. On this machine, Simulink tasks should be visual-first: open the model in a visible Simulink window before doing substantial automated modeling or simulation so the user can watch the process.
| File | Kind | Size |
|---|---|---|
| SKILL.md | skill md | 9.5 KB |
| references/excitation-checks.md | markdown | 5.8 KB |
| scripts/mas_dist_enter.m | other | 21.8 KB |
| scripts/mas_model_check.m | other | 2.8 KB |
| tests/test_dist_enter.m | other | 14.0 KB |
| tests/test_model_check.m | other | 1.0 KB |
references/excitation-checks.md
View on GitHub# Excitation Checks: Did the Disturbance Reach the Plant?
A simulation can look right for the wrong reason. Phase 3B.2 changed a load
parameter, saw the output move, and accepted the run; the parameter had only
reached a controller gain, not the plant. The opposite also happens: a
correctly applied disturbance produces no output change because the output is
insensitive by construction, and a curve-only check calls that a failure.
`mas_dist_enter` walks the chain in five separate steps and reports each one.
```matlab
r = mas_dist_enter(cfg);
r.verdict % PASS | FAIL | UNDETERMINED
r.evidenceQuality % VERIFIED | PARTIAL | NOT VERIFIED
r.reasons % PARAM_NOT_ENTERED_PLANT, OUTPUT_UNCHANGED, ...
r.before / r.after % requested and observed parameter values, levels, states
r.effectiveTime % when the change actually took effect
```
## The chain
| Step | Evidence | Missing evidence means |
|---|---|---|
| requested change | `cfg.base` vs `cfg.perturbed` | nothing to verify |
| plant receipt | `plantParams`, `paramLog`, `disturbanceLog`, `x0` | UNDETERMINED |
| effect | output delta, or internal state delta when insensitive | FAIL / UNDETERMINED |
| timing | log change time, else first response divergence | UNDETERMINED |
| independent prediction | `cfg.expect.delta` from an independent calculation | PARTIAL |
A changed field that is absent from an existing `plantParams` is a FAIL: the
plant reported what it consumes, and it does not consume that field. A missing
`plantParams` is UNDETERMINED: there is no evidence either way.
## Configuration
```matlab
cfg.name = 'load step';
cfg.base = struct('R', 1);
cfg.perturbed = struct('R', 2);
cfg.tInject = 0.5;
cfg.simFcn = @(p) run_case(p); % returns t, y, x, plantParams, ...
cfg.expect = struct('direction','increase', 'delta',1.0, 'tol',0.02, ...
'insensitive',false, 'minRel',1e-8, ...
'timeTol',0.02, 'maxResponseDelay',0.2, 'window',0.1);
```
`simFcn` must return:
- `t`, `y` — required, same length.
- `x` — internal states; required when `expect.insensitive` is true.
- `plantParams` — the parameter values the plant actually used at the end.
- `paramLog` — optional `struct('t', t, 'R', rTrace, ...)`.
- `disturbanceLog` — optional `struct('t', t, 'value', uTrace)` recorded at the
plant input, after every gain and switch between the source and the plant.
- `x0` or `initialState` — optional struct of actual initial states.
Changed fields are parameters by default. Declare exceptions explicitly:
```matlab
cfg.inputFields = {'u0'}; % checked against disturbanceLog
cfg.stateFields = {'x0'}; % checked against x0/initialState
```
`disturbanceLog` must record the signal that reaches the plant, not an enable
flag. A flag that steps from 0 to 1 while a gain is zero proves nothing.
## Timing
A log-based change must occur at `tInject` within `timeTol`. When only the
response is available, the first divergence is allowed to lag by
`maxResponseDelay`; this is a response time, not an injection time, and the
report says so (`r.effectiveTimeSource = 'response'`). A change before
`tInject` is always a timing failure.
## Insensitive outputs
When `expect.insensitive` is true, output change is not required and is not
evidence. The verifier requires a change in `x`:
- state changed -> PASS for internal evidence;
- states present but unchanged -> FAIL `INTERNAL_EVIDENCE`;
- no state trace -> UNDETERMINED, never PASS.
This is the case that a curve-only acceptance rule gets wrong in both
directions. If the output is theoretically insensitive, inspect states,
parameters, or derivatives; do not infer propagation from the output.
## Independent prediction
`expect.delta` must come from a closed-form solution, a separately implemented
reference, or another tool — not from the same simulation being checked. The
measured value is the mean over the final `window` fraction of samples. Make
the window match the prediction: for a final-value prediction at `t = 1.5`,
use one sample (`window = 1/numel(t)`).
If no prediction is supplied, the run can still PASS but evidence quality is
PARTIAL. A PASS is never upgraded to VERIFIED without all four: plant receipt,
timing, effect, and prediction.
## Simulink instrumentation recipe
1. Read the parameter in the plant subsystem from a workspace variable, and log
the value the plant used (`plantParams`) after the run.
2. Insert a `To Workspace` block on the plant input, after all gains and
switches; save it as a timeseries for `disturbanceLog`.
3. Log the internal state that should move when the output is insensitive.
4. Set the Step block's `Time` from the same `tInject` used by the verifier.
5. Run base and perturbed cases with `sim`, and pass both result structs'
evidence to `simFcn`.
6. Keep `mas_model_check` for L0-L3; `mas_dist_enter` answers a different
question and does not replace it.
## What the test suite pins
`tests/test_dist_enter.m` runs 19 cases: 15 model-free cases and four real
`.slx` variants (proper, zero amplitude, controller-only, late step).
The model-free set covers a correct run, a disconnected disturbance, a
controller-only update, a late step, an insensitive output with a changing
state, an insensitive output with no change, wrong amplitude, wrong direction,
missing plant evidence, a simulation error, no prediction, an input-amplitude
change (`inputFields`), an initial-state change (`stateFields`), and missing
input/state evidence. The last four exist because a disturbance is not always a
parameter: a changed input amplitude or initial state must also be traced to the
plant, and a missing log for either is UNDETERMINED rather than PASS.
A verifier that only looks at the output passes B, C, and D. A verifier that
only looks at parameters fails E. Both are required.
Related skills
| Skill | Stars | Updated | Works with | Status | Install |
|---|---|---|---|---|---|
| brainstormingobra/superpowersYou MUST use this before any creative work - creating features, building components, adding functionality, modifying behavior, or planning anything new, in software or out of it (a talk, a business, a renovation). | Stars: 323k | Updated | Claude CodeCodex | Verified | Install |
| brand-guidelinesanthropics/skillsApplies Anthropic's official brand colors and typography to any sort of artifact that may benefit from having Anthropic's look-and-feel. Use it when brand colors or style guidelines, visual formatting, or company design standards apply. | Stars: 198k | Updated | Claude CodeCodex | Verified | Install |
| frontend-designanthropics/skillsGuidance for distinctive, intentional visual design when building new UI or reshaping an existing one. Helps with aesthetic direction, typography, and making choices that don't read as templated defaults. | Stars: 198k | Updated | Claude CodeCodex | Verified | Install |
| mcp-builderanthropics/skillsGuide for creating high-quality MCP (Model Context Protocol) servers that enable LLMs to interact with external services through well-designed tools. Use when building MCP servers to integrate external APIs or services, whether in Python (FastMCP) or Node/TypeScript (MCP SDK). | Stars: 198k | Updated | Claude CodeCodex | Verified | Install |