Review a robot cell application built on the Wandelbots NOVA Python SDK (wandelbots-nova) for safety, motion, PLC/IO, async runtime, performance, lifecycle, device handling and NOVA SDK usage, and report findings with severity, evidence and concrete fixes. Use when the user asks to review, audit, check, lint or harden a NOVA app, a @nova.program, a NOVAx app or any robot application; asks about best practices, common pitfalls, cycle time, safety or commissioning readiness; or asks 'is my robot code OK?'.

references/rules/io.md

View on GitHub
# PLC / IO (IO)

## IO-001 · Handshakes are full request/ack cycles
`severity: error` · `scope: robotics` · `detect: static+review`

**Rule.** Use four-phase handshakes: set request → wait for ack high (timeout) → reset request →
wait for ack low (timeout). The same applies to device control words (e.g. gripper control word →
status bit).

```python
import asyncio
from nova.utils.io import set_bus_io_value, wait_for_bus_io


async def handshake(req: str, ack: str, timeout_s: float = 5.0) -> None:
    await set_bus_io_value({req: True})
    async with asyncio.timeout(timeout_s):
        await wait_for_bus_io([ack], on_change=lambda c: c[ack].new_value is True)
    await set_bus_io_value({req: False})
    async with asyncio.timeout(timeout_s):
        await wait_for_bus_io([ack], on_change=lambda c: c[ack].new_value is False)
```

**Observed.** Skipping the second half caused the gripper to ignore new parameters (plausibility
error codes).

---

## IO-002 · Every IO wait has a timeout and a predicate
`severity: error` · `scope: robotics` · `detect: static`

**Rule.** No unbounded wait on an IO signal. Each wait has a timeout that raises a descriptive error
naming the signal and the expected value. The timeout must not be optional, and it must not default
to 0 (meaning "infinite").

**Detect.** `wait_for_bus_io(` / `wait_for_bool_io(` without an enclosing timeout; `while not
read(...)` loops without deadline; timeout parameters with `0`/`None` defaults.

NOVA: neither `nova.utils.io.wait_for_bus_io` nor `wait_for_bool_io` has a timeout parameter.
Wrap them (see `nova-sdk-mapping.md`, IO-002).

---

## IO-003 · Read related signals atomically
`severity: warning` · `scope: robotics` · `detect: static`

**Rule.** When a decision depends on several signals, read them in **one** call and evaluate
against that snapshot. Sequential single-signal reads can mix states from different PLC cycles.

NOVA: `nova.utils.io.get_bus_io_value([a, b, c])` instead of several `controller.read(...)`.

---

## IO-004 · Validate the IO map at startup
`severity: warning` · `scope: robotics` · `detect: review`

**Rule.** At startup, verify that every signal the code references exists in the configured IO map
with the expected direction and type. Fail fast with a list of missing signals.

---

## IO-005 · Signal names come from generated symbols
`severity: warning` · `scope: robotics` · `detect: static`

**Rule.** Generate a symbol module from the PLC tag export (TIA/UDT/XML) and reference signals via
those symbols. String literals for signal names are typos that only surface at runtime. Regenerate
as a build step.

**Detect.** String literals matching `^(In|Out)\.` (or the project's prefix) outside the generated
module and config; string literals as the IO key of `io_write`, `read`, `write`,
`wait_for_bool_io`, `get_bus_io_value`, `set_bus_io_value`, `wait_for_bus_io`.

---

## IO-006 · Deduplicate triggers and job selection
`severity: warning` · `scope: robotics` · `detect: review`

**Rule.** When job selection is level-based (a "ready" flag stays high), the dispatcher must not
enqueue the same job again while it is pending or running. Duplicates are rejected visibly
(logged), not dropped silently.

---

## IO-007 · Consistent signal naming convention
`severity: info` · `scope: robotics` · `detect: static`

**Rule.** Example convention: `<Dir>.<Domain>[.<Station>].<Signal>`, with `Dir ∈ {In, Out}` from the
robot's view, `Domain ∈ {Sys, Grp, App}`, PascalCase signals and semantic suffixes (`Rdy`, `Act`,
`Done`, `HS`, `Ok`).
rea-analysis-optimizationmorluto/reaOptimize REA providers and shared analysis workflows for agent context, latency, CPU, and memory while preserving correctness and Evidence. Use for analysis bottlenecks and cache or query design; CI/test-suite optimization belongs to rea-ci-tests-audit.Stars: 472kUpdated Claude CodeCodexVerifiedInstall
rea-ci-tests-auditmorluto/reaAudit REA CI and test suites for correctness, fixture drift, false passes, and measured performance; use for suite or workflow investigations and efficiency changes, rather than ordinary feature testing or a single test failure.Stars: 472kUpdated Claude CodeCodexVerifiedInstall
rea-tool-designmorluto/reaAudit, investigate, design, or change REA investigation tools, CLI/MCP contracts, provider capabilities, and Evidence semantics.Stars: 472kUpdated Claude CodeCodexVerifiedInstall
ponytail-auditDietrichGebert/ponytailQuality audit of the whole repo: bugs, security, real load, missing tests, speed, and what to delete. Most important first.Stars: 194kUpdated Claude CodeCodexVerifiedInstall