VerifiedPort MATLAB Data Acquisition Toolbox code from the discouraged (legacy) session-based interface (daq.createSession, addAnalogInputChannel, startBackground, DataAvailable listeners, queueOutputData, wait) to the recommended DataAcquisition interface (daq("ni"), addinput, start, ScansAvailableFcn, write, preload). Use when migrating legacy DAQ scripts, converting session-API calls, working with DataAcquisition objects, writing multi-feature DAQ scripts that combine triggers, callbacks, continuous acquisition, or analog output. Also use when a user says their DAQ script "used to work" or "errors on R20XX", since modernizing legacy session-API code is a frequent fix for those failures. Trigger keywords: daq, DAQ, NI, session interface, addtrigger, addclock, ScansAvailableFcn, ScansRequiredFcn, daq.createSession, addAnalogInputChannel, startBackground, queueOutputData, DataAvailable, evt.Data, evt.TimeStamps, wait(d), preload, discouraged, legacy, modernize, R2020a.
| File | Kind | Size |
|---|---|---|
| SKILL.md | skill md | 17.8 KB |
| manifest.yaml | config | 477 B |
| references/callback-state-patterns.md | markdown | 7.5 KB |
| references/canonical-snippets.md | markdown | 5.7 KB |
| references/session-to-modern-mapping.md | markdown | 13.4 KB |
| scripts/verifyDataAcquisition.m | other | 7.4 KB |
references/callback-state-patterns.md
View on GitHub# Callback State Patterns
When a `ScansAvailableFcn` or `ScansRequiredFcn` needs to maintain state across fires (running counters, phase accumulators, latch flags, file handles), four mechanisms are available. Three work, one fails silently. This file is the decision guide.
## Quick decision
| Need | Use |
|----------------------------------------------------------------------|-------------------------------------------|
| Simple scalar counter or flag, in a function-form script | **Nested function** (Pattern A) |
| Complex state shared across multiple callbacks and external code | **Handle class wrapper** (Pattern B) |
| Quick prototype, single callback, can re-create state each fire | **Anonymous-function closure** (Pattern C, with caveats) |
| Code already passes `d` everywhere and you don't want extra files | **Whole-struct UserData rewrite** (Pattern D, advanced) |
**Never use:** `src.UserData.X = src.UserData.X + ...` field mutation (see anti-pattern below).
## Pattern A — Nested function (recommended default)
The callback is a nested function inside the entry function. Local variables in the entry function are captured by **reference** in nested functions, so updates persist.
```matlab
function runStreamingAcquisition()
d = daq("ni");
addinput(d, "Dev1", "ai0", "Voltage");
d.Rate = 1000;
d.ScansAvailableFcnCount = 200;
scansRead = 0;
target = d.Rate * 5;
d.ScansAvailableFcn = @(src, ~) onBlock(src);
d.ErrorOccurredFcn = @(~, evt) fprintf("DAQ error: %s\n", evt.Error.message);
start(d, "Continuous");
while d.Running
pause(0.05);
end
function onBlock(src)
data = read(src, src.ScansAvailableFcnCount, "OutputFormat", "Matrix");
scansRead = scansRead + size(data, 1);
if scansRead >= target
stop(src);
end
end
end
```
**When to use:** the simplest correct form. Prefer this when the whole acquisition fits in one entry function.
**When NOT to use:** when state needs to be inspected from outside the entry function, or shared between multiple unrelated functions.
## Pattern B — Handle class wrapper
A `handle` class instance is passed by reference. Mutations to its properties persist across all references.
```matlab
classdef AcquisitionState < handle
properties
ScansRead (1,1) double = 0
Target (1,1) double
end
methods
function obj = AcquisitionState(target)
obj.Target = target;
end
end
end
% Usage:
state = AcquisitionState(d.Rate * 5);
d.ScansAvailableFcn = @(src, ~) onBlock(src, state);
d.ErrorOccurredFcn = @(~, evt) fprintf("DAQ error: %s\n", evt.Error.message);
start(d, "Continuous");
while d.Running
pause(0.05);
end
function onBlock(src, state)
data = read(src, src.ScansAvailableFcnCount, "OutputFormat", "Matrix");
state.ScansRead = state.ScansRead + size(data, 1);
if state.ScansRead >= state.Target
stop(src);
end
end
```
**When to use:** state is complex (multiple fields, methods like `reset()`, `summary()`), or callers outside the entry function need to read or modify it.
**Cost:** one additional class file. Worth it for nontrivial state.
## Pattern C — Anonymous-function closure (caveats)
Anonymous functions snapshot variables **by value** at creation time. They cannot mutate them.
```matlab
% This works:
gain = 0.5;
d.ScansAvailableFcn = @(src, ~) processBlock(src, gain);
% gain is captured by value; processBlock can read but not change it for next time.
% This DOES NOT work the way you might expect:
counter = 0;
d.ScansAvailableFcn = @(src, ~) (counter = counter + 1); % Not even valid MATLAB syntax
```
**When to use:** read-only state (constants, configuration values that don't change across fires).
**When NOT to use:** any state that needs to update across fires. Pattern A or B instead.
## Pattern D — Whole-struct UserData rewrite (advanced)
`d.UserData` is a property; assigning `d.UserData = newStruct` calls the property setter and persists. **Field mutation** through `d.UserData.X = ...` from inside a callback does **not** persist reliably — see anti-pattern.
```matlab
d.UserData = struct('ScansRead', 0, 'Target', d.Rate * 5);
d.ScansAvailableFcn = @(src, ~) onBlock(src);
d.ErrorOccurredFcn = @(~, evt) fprintf("DAQ error: %s\n", evt.Error.message);
start(d, "Continuous");
function onBlock(src)
data = read(src, src.ScansAvailableFcnCount, "OutputFormat", "Matrix");
s = src.UserData; % copy whole struct out
s.ScansRead = s.ScansRead + size(data, 1);
src.UserData = s; % whole-struct assignment back
if s.ScansRead >= s.Target
stop(src);
end
end
```
**When to use:** state belongs conceptually with the device and you don't want a separate class file. The whole-struct rewrite (`s = src.UserData; ... ; src.UserData = s`) is the only safe `UserData` mutation form.
**Verify after:** read `d.UserData.<field>` after a few callback fires and confirm the value advanced. Don't trust scan-count totals as a proxy — `NumScansAcquired` advances independent of your callback state.
## Anti-pattern — `src.UserData.X = src.UserData.X + …` field mutation
```matlab
% DO NOT DO THIS — field mutation inside the callback does not persist.
function onBlock(src)
data = read(src, src.ScansAvailableFcnCount, "OutputFormat", "Matrix");
src.UserData.ScansRead = src.UserData.ScansRead + size(data, 1); % SILENTLY FAILS
if src.UserData.ScansRead >= src.UserData.Target
stop(src);
end
end
```
This pattern reads `src.UserData` (a copy), mutates a field on the copy, and the assignment back through `src.UserData.ScansRead = …` does not propagate. The counter resets every fire; closed-loop control laws output zero forever; running totals stay at the increment of a single block.
**Why it's silent:** the syntax is legal MATLAB and produces no error. The field appears to update *within* the same callback fire, but the next fire sees the original value. Listener exception handling never sees a problem because there is no exception.
**Test for it:** insert `fprintf("UserData.X = %d\n", src.UserData.X);` at the top of the callback. If the value never advances across fires, this anti-pattern is in play.
## Summary table
| Pattern | Persists across fires? | When to use | Notes |
|--------------------------------------|------------------------|--------------------------------------------|------------------------------------------------------|
| A. Nested function | Yes (by reference) | Default for in-script callbacks | Captures everything in scope |
| B. Handle class | Yes (by reference) | Complex state, external access, methods | Extra class file |
| C. Anonymous closure (read-only) | N/A — read only | Configuration constants | Cannot mutate |
| D. Whole-struct UserData rewrite | Yes (whole-property) | Lightweight, self-contained on `d` | Only safe form: `s = src.UserData; …; src.UserData = s` |
| **Anti: field mutation on UserData** | **No — silent failure**| Never | The most-common silent bug in DAQ callbacks |
----
Copyright 2026 The MathWorks, Inc.
----
Related skills
| Skill | Stars | Updated | Works with | Status | Install |
|---|---|---|---|---|---|
| receiving-code-reviewobra/superpowersUse when receiving code review feedback, before implementing suggestions, especially if feedback seems unclear or technically questionable - requires technical rigor and verification, not performative agreement or blind implementation | Stars: 321k | Updated | Claude CodeCodex | Verified | Install |
| requesting-code-reviewobra/superpowersUse when completing tasks, implementing major features, or before merging to verify work meets requirements | Stars: 321k | Updated | Claude CodeCodex | Verified | Install |
| using-git-worktreesobra/superpowersUse when starting feature work that needs isolation from current workspace or before executing implementation plans - ensures an isolated workspace exists via native tools or git worktree fallback | Stars: 321k | Updated | Claude CodeCodex | Verified | Install |
| verification-before-completionobra/superpowersUse when about to claim work is complete, fixed, or passing, before committing or creating PRs - requires running verification commands and confirming output before making any success claims; evidence before assertions always | Stars: 321k | Updated | Claude CodeCodex | Verified | Install |