Select and use Audio Toolbox acoustic, psychoacoustic, and speech quality metrics. Use when computing loudness, sharpness, roughness, fluctuation strength, noise criteria (NC/RNC/RC), speech transmission index (STI), speech intelligibility index (SII), speech quality (ViSQOL, STOI), SPL, reverberation time (RT60), tone-to-noise ratio, or prominence ratio. Also use when asked about PESQ, POLQA, calibration factor, EBU R 128, LUFS, HVAC noise, background noise evaluation, or how to measure audio quality or noise compliance. Covers calibration, standard selection, signal alignment, and the complete function inventory including what does NOT exist.

references/rt60-measurement.md

View on GitHub
# RT60 Measurement

Guidance for selecting parameters, interpreting results, and guiding user workflows for `rt60`.

## Intake Questions

### 1. What is the purpose?

| Purpose | What RT60 tells them |
|---------|---------------------|
| Room design verification | Does the finished room meet the acoustic design target? |
| Speech intelligibility assessment | Is the room too reverberant for speech? (RT60 > 1.5s generally problematic) |
| Music venue evaluation | Is the reverberance appropriate for the genre? |
| Noise control / absorption planning | How much absorption is needed to reduce RT60 to target? |
| Compliance with building standards | Does the room meet standards like BB93, ANSI S12.60? |
| STI context | Explaining why STI is low — reverberance is the usual culprit |

### 2. Do they have an impulse response?

- **Yes:** Pass directly to `rt60(ir, fs)`
- **No, need to measure:** See the `matlab-play-record-audio` skill for the IR capture workflow (`sweeptone` generation, playback/recording through the room, and `impzest` deconvolution). This skill covers what to do *with* the IR once obtained.

**IR requirements:** The IR must include the noise floor — continue recording after the reverberation tail has fully decayed. The function assumes at least the last 10% of the IR duration corresponds to noise (used for noise floor estimation). For large reverberant spaces (churches, concert halls), use longer captures (3–5 s minimum).

### 3. What analysis bandwidth?

| Bandwidth | Output | When to use |
|-----------|--------|-------------|
| `"1 octave"` (default) | RT60 per octave band | Standard building acoustics, compliance checks, general room characterization |
| `"1/3 octave"` | RT60 per 1/3-octave band | Detailed analysis, research, when absorption varies significantly within octave bands |

### 4. Noise compensation method

| Method | Behavior | When to use |
|--------|----------|-------------|
| `"truncate-correct"` (default) | Lundby algorithm: estimates noise floor, truncates IR at noise intersection, compensates per ISO 3382-1 | Standard-compliant measurements; most situations |
| `"subtract-truncate-correct"` | Additionally subtracts noise floor before truncation | When the noise floor is relatively high; shown to introduce less systematic error in noisy conditions (non-ISO) |

Default is appropriate for most users. Only suggest `"subtract-truncate-correct"` when IRs have marginal SNR and the user does not require strict ISO 3382-1 compliance.

### 5. Measurement conditions (ISO 3382-2)

ISO 3382-2 defines three measurement levels (Table 1, section 4.3):

| Level | Source-mic combinations | Source positions | Mic positions | Accuracy (octave) |
|-------|------------------------|-----------------|---------------|-------------------|
| Survey | ≥2 | ≥1 | ≥2 | ~10% |
| Engineering | ≥6 | ≥2 | ≥2 | ~5% |
| Precision | ≥12 | ≥2 | ≥3 | ~2.5% |

**Position requirements (section 4.3.1):**
- Mic positions **shall** be at least half a wavelength apart (~2 m for typical frequency range)
- Distance from mic to nearest reflecting surface (including floor) **should preferably** be at least a quarter wavelength (~1 m)
- Minimum source-to-mic distance depends on room volume and expected RT60: d_min = 2×sqrt(V / (c×T))
- Symmetric positions **shall** be avoided

**Additional conditions:**
- **Room state:** Furnishings in place as intended for use (unfurnished rooms measure much longer RT60)
- **Background noise (section 5.2.1):** Source level **shall** be at least 35 dB above background noise for T20, or 45 dB for T30
- **Reliability (ISO 3382-1 section 7.3):** Results **shall** satisfy B×T > 16, where B is the filter bandwidth (Hz) and T is the measured reverberation time (s). Low-frequency bands with short RT60 may fail this criterion.

## Interpreting RT60 Results

### T20 vs T30 vs EDT

| Metric | Evaluation Range | What it represents |
|--------|-----------------|-------------------|
| EDT (Early Decay Time) | 0 to −10 dB | Perceived reverberance — what listeners experience (first part of decay dominates perception) |
| T20 | −5 to −25 dB | Reverberation time extrapolated from 20 dB range — more robust to noise than T30 |
| T30 | −5 to −35 dB | Reverberation time from 30 dB range — more accurate but requires higher IR SNR |

**Guidance:**
- **EDT** correlates best with subjective impression of reverberance — use when reporting "how reverberant the room feels"
- **T30** is the standard metric for compliance and design verification (ISO 3382 prefers T30 when SNR allows)
- **T20** is a fallback when background noise limits the usable decay range
- **Topt** uses the decay range yielding the best linear fit while remaining 10 dB above the detected noise floor — useful when neither T20 nor T30 gives a clean fit
- In a well-diffused room, EDT ≈ T20 ≈ T30. If they diverge significantly:
  - EDT << T20/T30: Strong early reflections followed by a long tail (common with localized absorption near source/receiver)
  - EDT >> T20/T30: Weak early field (unusual — check measurement)
- Metrics return **NaN** when the detected noise floor does not allow 10 dB of headroom over the evaluation range — this indicates insufficient IR SNR for that metric in that band

### Additional Output Metrics

The `rt60` output table includes metrics beyond reverberation time that are useful for room quality assessment:

| Metric | Standard | Definition | Application |
|--------|----------|-----------|-------------|
| C50 | ISO 3382-1 | Clarity (50 ms cutoff) — early-to-late energy ratio (dB) | Speech clarity: C50 > 0 dB is generally acceptable; higher is clearer |
| C80 | ISO 3382-1 | Clarity (80 ms cutoff) — early-to-late energy ratio (dB) | Music clarity: C80 between −2 and +2 dB is optimal for most genres |
| D50 | ISO 3382-1 | Definition (50 ms cutoff) — early-to-total energy ratio (0 to 1) | Speech: D50 > 0.5 generally indicates adequate articulation |
| TS | ISO 3382-1 | Center time — center of gravity of the squared IR (seconds) | Lower TS = more early energy; correlates with clarity perception |
| DegreeOfNonLinearity | ISO 3382-2 B.2 | 1000×(1−r²) for the linear fit of each decay range (N-by-4 matrix: EDT, T20, T30, Topt) | Values 0–5 typical; high values suggest non-exponential decay |
| Curvature | ISO 3382-2 B.3 | `100 × (T30/T20 − 1)` (signed) | Values −5 to 5 typical; magnitude indicates divergence between T20 and T30; sign indicates direction |

**When to report which metrics:**
- Room design compliance: T30 (or T20), Curvature
- Speech room assessment: T30, EDT, C50, D50
- Music venue assessment: T30, EDT, C80, TS
- Measurement quality check: DegreeOfNonLinearity, Curvature

### Target RT60 Values by Space Type

| Space | Target RT60 (s) | Standard/Reference |
|-------|----------------|-------------------|
| Recording studio / control room | 0.2–0.4 | — |
| Classroom (≤283 m³) | ≤ 0.6 | ANSI S12.60, BB93 (UK) |
| Classroom (>283 m³) | ≤ 0.7 | ANSI S12.60 |
| Conference room | 0.4–0.7 | — |
| Lecture hall | 0.7–1.0 | — |
| Open plan office | 0.5–0.8 | — |
| Concert hall (symphony) | 1.8–2.2 | — |
| Concert hall (chamber music) | 1.4–1.8 | — |
| Opera house | 1.2–1.6 | — |
| Church (liturgical music) | 2.0–4.0 | — |
| Worship (speech-primary) | 0.8–1.2 | — |
| Hospital patient room | 0.4–0.6 | — |

### RT60 vs Frequency

RT60 typically varies with frequency:
- **Low frequencies (125–250 Hz):** Often longer (less absorption from typical materials at LF)
- **Mid frequencies (500–1000 Hz):** Reference range — most targets are specified here
- **High frequencies (2000–8000 Hz):** Often shorter due to air absorption and porous absorber effectiveness

**Common patterns and implications:**
| Pattern | Cause | Action |
|---------|-------|--------|
| Flat across frequency | Well-treated room with broadband absorption | Ideal for speech and music |
| Rising at low frequency | Insufficient bass trapping | Add bass traps, panel absorbers, or membrane absorbers |
| Falling at high frequency | Excessive HF absorption or air absorption in large rooms | Normal for large volumes; add diffusion if HF liveness desired |
| Spike at one frequency | Room mode or resonance | Treat the specific mode with targeted absorption |

### Relationship to STI

RT60 and STI are directly related — reverberation is the primary degrader of speech intelligibility in quiet rooms. Approximate STI for purely diffuse exponential-decay rooms with no ambient noise (computed using `speechTransmissionIndex` on synthetic IRs with `AddOperationalAmbientNoise=false`):

| RT60 (s) | Approximate STI | IEC 60268-16 Category |
|-----------|----------------|----------------------|
| 0.5 | 0.74 | A |
| 1.0 | 0.60 | D |
| 1.5 | 0.50 | G |
| 2.0 | 0.44 | H–I |
| 3.0 | 0.36 | U |
| 5.0 | 0.27 | U |

Adding ambient noise can only reduce STI below these values.

If the user has STI concerns:
- Short RT60 but low STI → noise is the dominant factor, not reverberation
- Long RT60 and low STI → reduce RT60 with absorption (most effective intervention)
- Use `rt60` to diagnose, then `speechTransmissionIndex` to quantify the intelligibility impact

### Assessing Measurement Quality

Use `DegreeOfNonLinearity` and `Curvature` from the output table to assess whether results are trustworthy:

- **DegreeOfNonLinearity (ξ):** Defined as 1000×(1−r²), where r² is the correlation coefficient of the linear fit to the energy decay curve. ξ = 0 means a perfect linear fit (r² = 1). ISO 3382-2 B.2 states typical values are 0–5. To interpret as r²: r² = 1 − ξ/1000 (e.g., ξ = 5 → r² = 0.995).
- **Curvature:** Quantifies the divergence between T30 and T20. Values near 0 indicate consistent decay; |Curvature| > 5 suggests coupled volumes or non-diffuse conditions (ISO 3382-2 B.3).
- **NaN values:** If a metric returns NaN, the detected noise floor does not provide enough headroom for that evaluation range in that band — use a metric with a shorter evaluation range (T20 instead of T30) or re-record with a stronger source.

## Common Scenarios

### Scenario: Classroom Compliance Check

1. Obtain room IR (see `matlab-play-record-audio` for capture workflow; sine sweep method preferred for SNR)
2. Compute: `rtsummary = rt60(ir, fs, Bandwidth="1 octave")`
3. Read T30 (or T20 if insufficient SNR) at 500 Hz, 1000 Hz, 2000 Hz
4. Average these three mid-frequency bands → this is the compliance metric
5. Compare to target: ANSI S12.60 requires ≤ 0.6 s for rooms ≤ 283 m³

### Scenario: Diagnose Low STI

1. Measure STI: `speechTransmissionIndex(ir, fs, OperationalNoiseLevel="NC-35")`
2. If STI is low, measure RT60: `rtsummary = rt60(ir, fs)`
3. Examine frequency-dependent RT60 — which bands are too long?
4. Cross-reference with MTI output from STI: low MTI at specific bands + long RT60 at those bands = reverberation-driven problem
5. Recommend treatment: add absorption in the frequency bands where RT60 exceeds the target

### Scenario: Concert Hall Evaluation

1. Measure at multiple source-receiver positions (≥6 per ISO 3382-1)
2. Compute per-position RT60 and EDT
3. Report: mean T30 across positions (spatial average), EDT for perceived character
4. Compare T30 to genre target (1.8–2.2 s for symphony, 1.4–1.8 for chamber)
5. Check frequency balance: flat or gently rising at LF is preferred for warmth

## Troubleshooting

### Visual inspection of decay curves

The primary troubleshooting step is to call `rt60` with no output arguments to generate the convenience plot. The plot shows:
- **Top panel:** RT60 values (EDT, T20, T30, Topt) across octave bands — click a band to inspect it
- **Bottom panel:** The energy decay curve (EDC) for the selected band with linear fit lines overlaid

Inspect the fit lines against the EDC to identify:
- **Noise floor intersection** — where the EDC flattens, indicating the usable decay range
- **Double-slope decay (coupled rooms)** — a "hump" or change in slope in the tail, where energy from an adjacent coupled space arrives. This appears as a concave EDC that doesn't follow a single straight line.
- **Poor fit** — the linear regression doesn't track the actual decay

### Adjusting parameters for better fits

If the decay curves show poor fits, adjust `FilterOrder`, `FilterDirection`, and `NoiseCompensation` and monitor `DegreeOfNonLinearity` and `Curvature` to find the combination that best characterizes the decay:

| Parameter | Options | When to adjust |
|-----------|---------|----------------|
| `FilterOrder` | 2 (default), 4, 6, ... | Higher order gives sharper band separation — try when adjacent bands bleed energy |
| `FilterDirection` | `"forward"` (default), `"backward"` | Backward filtering eliminates filter ringing at the start of the decay — try when EDT looks unreliable |
| `NoiseCompensation` | `"truncate-correct"` (default), `"subtract-truncate-correct"` | Subtract mode reduces bias from high noise floors — try when T30 shows large DegreeOfNonLinearity |

### Common issues

| Observation | Likely Cause | Action |
|-------------|-------------|--------|
| T30 varies wildly between bands | Normal if room has frequency-dependent absorption | Expected behavior; focus on mid-frequency average for compliance |
| T30 > T20 by large margin | Noise floor contaminating the lower part of the decay | Trust T20; re-measure with higher source level if T30 needed |
| Large Curvature with concave EDC | Coupled room — energy returns from adjacent space | Report T20 (less affected); note coupled-room behavior in results |
| EDT much shorter than T30 | Strong early reflections near measurement position | Indicates non-diffuse field; measure at more positions and average |
| Very short RT60 (<0.1 s) | IR too short, or measurement captured direct sound only | Verify IR contains the full decay; use longer measurement window |
| RT60 result shows NaN or unreliable | Insufficient signal-to-noise ratio in that band | Check noise floor; use T20 instead of T30; re-record with stronger source |
| Different results from different positions | Normal room mode behavior — spatial variation is expected | Average across ≥3 positions per ISO 3382; report range |
| RT60 doesn't match subjective impression | EDT correlates better with perception than T30 | Report EDT alongside T30 for perceptual assessment |
| Measured RT60 seems implausible for the room | Measurement error, or unexpected room conditions | Use `predictRT60` with known room dimensions and materials as a sanity check against the measured value |

----

Copyright 2026 The MathWorks, Inc.

----
slack-gif-creatoranthropics/skillsKnowledge and utilities for creating animated GIFs optimized for Slack. Provides constraints, validation tools, and animation concepts. Use when users request animated GIFs for Slack like "make me a GIF of X doing Y for Slack."Stars: 198kUpdated Claude CodeCodexVerifiedInstall
ponytailDietrichGebert/ponytailLazy senior dev mode for any coding task: the smallest change that fully solves it, and a reply a busy human understands in one read.Stars: 194kUpdated Claude CodeCodexVerifiedInstall
ponytail-debtDietrichGebert/ponytailHarvest every shortcut: comment into one debt ledger, so deferrals get tracked instead of forgotten. One-shot report.Stars: 194kUpdated Claude CodeCodexVerifiedInstall
ponytail-debtDietrichGebert/ponytailList every `shortcut:` comment (and older `ponytail:` ones) as a debt ledger. One-shot report, changes nothing. Use for "ponytail debt", "what did ponytail defer", "list the shortcuts", /ponytail-debt.Stars: 194kUpdated Claude CodeCodexVerifiedInstall