VerifiedExtract structured specifications from electronic component datasheet PDFs — pinouts, electrical characteristics, peripherals, topology, and features. Cache extractions per project for consumption by schematic and PCB analyzers. Primary consumer infrastructure for `kicad`, `emc`, `spice`, and `thermal` analyzers. Use this skill whenever the user asks to extract, verify, or read specs from a component datasheet; when analyzers need verified IC knowledge (EN pin thresholds, PG presence, USB peripheral speed); or when a review mentions datasheet coverage, extraction quality, or per-MPN specifications. Also triggers on "extract this datasheet", "what are the specs for MPN X", "verify datasheet extraction", or "check pin functions for part Y".
examples/abm8g-106-12.000mhz-t.json
View on GitHub{
"base": {
"absolute_max": {
"T_storage": [
{
"condition": null,
"evidence": {
"confidence": "high",
"method": "table",
"page": 1,
"section": "KEY ELECTRICAL SPECIFICATIONS"
},
"max": 85,
"min": -40,
"notes": "Storage temperature range",
"typ": null,
"unit": "\u00b0C"
}
],
"drive_level": [
{
"condition": null,
"evidence": {
"confidence": "high",
"method": "table",
"page": 1,
"section": "KEY ELECTRICAL SPECIFICATIONS"
},
"max": 0.0001,
"min": null,
"notes": "Maximum drive level: typ 10 \u00b5W, max 100 \u00b5W (stored in W)",
"typ": 1e-05,
"unit": "W"
}
]
},
"compliance": [
{
"evidence": {
"confidence": "high",
"method": "prose",
"page": 1,
"section": "Compliance"
},
"mark": "RoHS",
"rating": "RoHS II 2011/65/EU compliant"
}
],
"description": "Ultra miniature ceramic glass sealed SMD crystal, 12.000 MHz fundamental mode, 3.2 x 2.5 x 1.0 mm package.",
"esd": {},
"family": "AT-cut surface mount crystal resonator",
"moisture_sensitivity": null,
"package": {
"body_mm": {
"height": 1.0,
"length": 3.2,
"width": 2.5
},
"code": "ABM8G",
"evidence": {
"confidence": "high",
"method": "table",
"page": 1,
"section": "KEY ELECTRICAL SPECIFICATIONS"
},
"pin_count": 4,
"pitch_mm": 2.2,
"thermal_pad": false
},
"pin_relationships": [],
"pinout": [
{
"absolute_max": null,
"alt_functions": [],
"description": "Crystal terminal 1. Functionally interchangeable with pin 2.",
"drive_strength": null,
"evidence": {
"confidence": "high",
"method": "prose",
"page": 2,
"section": "MECHANICAL DIMENSIONS"
},
"is_5v_tolerant": null,
"name": "XTAL1",
"notes": "Pins 1 and 2 are the two crystal terminals; electrically symmetric. Connect to oscillator amp through CL=10 pF caps.",
"numbers": [
"1"
],
"power_domain": null,
"recommended": null,
"subtype": null,
"type": "passive"
},
{
"absolute_max": null,
"alt_functions": [],
"description": "Crystal terminal 2. Functionally interchangeable with pin 1.",
"drive_strength": null,
"evidence": {
"confidence": "high",
"method": "prose",
"page": 2,
"section": "MECHANICAL DIMENSIONS"
},
"is_5v_tolerant": null,
"name": "XTAL2",
"notes": "Pins 1 and 2 are the two crystal terminals; electrically symmetric.",
"numbers": [
"2"
],
"power_domain": null,
"recommended": null,
"subtype": null,
"type": "passive"
},
{
"absolute_max": null,
"alt_functions": [],
"description": "Case ground/shield pad. Provides electrostatic shielding.",
"drive_strength": null,
"evidence": {
"confidence": "high",
"method": "prose",
"page": 2,
"section": "MECHANICAL DIMENSIONS"
},
"is_5v_tolerant": null,
"name": "GND",
"notes": "Pins 3 and 4 are both labeled GND. Connect to PCB ground plane for EMI shielding.",
"numbers": [
"3"
],
"power_domain": null,
"recommended": null,
"subtype": null,
"type": "power_in"
},
{
"absolute_max": null,
"alt_functions": [],
"description": "Case ground/shield pad. Provides electrostatic shielding.",
"drive_strength": null,
"evidence": {
"confidence": "high",
"method": "prose",
"page": 2,
"section": "MECHANICAL DIMENSIONS"
},
"is_5v_tolerant": null,
"name": "GND",
"notes": "Pin 4 may have chamfer per raw material; does not affect electrical characteristics.",
"numbers": [
"4"
],
"power_domain": null,
"recommended": null,
"subtype": null,
"type": "power_in"
}
],
"recommended_operating": {
"T_operating": [
{
"condition": null,
"evidence": {
"confidence": "high",
"method": "table",
"page": 1,
"section": "KEY ELECTRICAL SPECIFICATIONS"
},
"max": 85,
"min": -40,
"notes": "Operating temperature range",
"typ": null,
"unit": "\u00b0C"
}
],
"load_capacitance": [
{
"condition": null,
"evidence": {
"confidence": "high",
"method": "table",
"page": 1,
"section": "KEY ELECTRICAL SPECIFICATIONS"
},
"max": null,
"min": null,
"notes": "CL = 10 pF specified for nominal frequency (stored in F)",
"typ": 1e-11,
"unit": "F"
}
]
},
"thermal": {}
},
"categories": [
"crystal"
],
"crystal": {
"aging": [
{
"condition": "first year @ 25\u00b0C \u00b13\u00b0C",
"evidence": {
"confidence": "high",
"method": "table",
"page": 1,
"section": "KEY ELECTRICAL SPECIFICATIONS"
},
"max": 3,
"min": -3,
"notes": "Datasheet column shows \u00b13 ppm; time window is first year",
"typ": null,
"unit": "ppm"
}
],
"crystal_type": "at_cut",
"drive_level_max": [
{
"condition": null,
"evidence": {
"confidence": "high",
"method": "table",
"page": 1,
"section": "KEY ELECTRICAL SPECIFICATIONS"
},
"max": 0.0001,
"min": null,
"notes": "Typ 10 \u00b5W, max 100 \u00b5W; stored in W",
"typ": 1e-05,
"unit": "W"
}
],
"esr_max": [
{
"condition": null,
"evidence": {
"confidence": "high",
"method": "table",
"page": 1,
"section": "KEY ELECTRICAL SPECIFICATIONS"
},
"max": 120,
"min": null,
"notes": "Equivalent series resistance R1 maximum",
"typ": null,
"unit": "\u03a9"
}
],
"frequency": [
{
"condition": null,
"evidence": {
"confidence": "high",
"method": "table",
"page": 1,
"section": "KEY ELECTRICAL SPECIFICATIONS"
},
"max": null,
"min": null,
"notes": "12.000 MHz nominal",
"typ": 12000000,
"unit": "Hz"
}
],
"frequency_stability": [
{
"condition": "over operating temp range -40 to +85\u00b0C, ref to +25\u00b0C",
"evidence": {
"confidence": "high",
"method": "table",
"page": 1,
"section": "KEY ELECTRICAL SPECIFICATIONS"
},
"max": 30,
"min": -30,
"notes": null,
"typ": null,
"unit": "ppm"
}
],
"frequency_tolerance": [
{
"condition": "@ 25\u00b0C",
"evidence": {
"confidence": "high",
"method": "table",
"page": 1,
"section": "KEY ELECTRICAL SPECIFICATIONS"
},
"max": 20,
"min": -20,
"notes": null,
"typ": null,
"unit": "ppm"
}
],
"load_capacitance": [
{
"condition": null,
"evidence": {
"confidence": "high",
"method": "table",
"page": 1,
"section": "KEY ELECTRICAL SPECIFICATIONS"
},
"max": null,
"min": null,
"notes": "10 pF typical",
"typ": 1e-11,
"unit": "F"
}
],
"mode": "fundamental",
"motional_capacitance": null,
"motional_inductance": null,
"operating_temp_range": [
{
"condition": null,
"evidence": {
"confidence": "high",
"method": "table",
"page": 1,
"section": "KEY ELECTRICAL SPECIFICATIONS"
},
"max": 85,
"min": -40,
"notes": null,
"typ": null,
"unit": "\u00b0C"
}
],
"package": {
"body_mm": {
"height": 1.0,
"length": 3.2,
"width": 2.5
},
"code": "ABM8G",
"evidence": {
"confidence": "high",
"method": "table",
"page": 2,
"section": "MECHANICAL DIMENSIONS"
}
}
},
"extraction": {
"extracted_at": "2026-04-27T22:10:35Z",
"extractor_schema_version": "1.0",
"extractor_scout": null,
"plan_ref": "ABM8G-106-12.000MHZ-T.plan.json",
"quality_score": 76
},
"schema_version": {
"base": "1.0",
"categories": {
"crystal": "1.0"
}
},
"source": {
"datasheet_date": "2018-03-19",
"datasheet_revision": null,
"family_ref": null,
"local_path": "datasheets/ABM8G-106-12.000MHZ-T.pdf",
"manufacturer": "Abracon",
"mpn": "ABM8G-106-12.000MHZ-T",
"page_count": 3,
"sha256": "sha256:03360289d6bd5f5d91a0c2a3e5d6dfe8c74516a2e286937d9e1c058df4c4cee7",
"source_url": null
}
}Related skills
| Skill | Stars | Updated | Works with | Status | Install |
|---|---|---|---|---|---|
| finishing-a-development-branchobra/superpowersUse when implementation is complete, all tests pass, and you need to decide how to integrate the work | Stars: 322k | Updated | Claude CodeCodex | Verified | Install |
| systematic-debuggingobra/superpowersUse when encountering any bug, test failure, or unexpected behavior, before proposing fixes | Stars: 322k | Updated | Claude CodeCodex | Verified | Install |
| test-driven-developmentobra/superpowersUse when implementing any feature or bugfix, before writing implementation code | Stars: 322k | Updated | Claude CodeCodex | Verified | Install |
| skill-creatoranthropics/skillsCreate new skills, modify and improve existing skills, and measure skill performance. Use when users want to create a skill from scratch, edit, or optimize an existing skill, run evals to test a skill, benchmark skill performance with variance analysis, or optimize a skill's description for better triggering accuracy. | Stars: 198k | Updated | Claude CodeCodex | Verified | Install |