Researches which building codes, accessibility standards and authority requirements (health department, fire marshal, state agency) apply to a scope or spec section, and which the project documents miss. Use for 'what codes apply', 'code check', 'ADA requirements', 'egress', 'health department'. Not for reading what the drawings or specs say (construction-guide).

FileKindSize
SKILL.mdskill md23.2 KB
agents/openai.yamlconfig292 B
references/discipline_notes.mdmarkdown1.9 KB
references/gap_report_template.mdmarkdown5.2 KB
references/schemas.yamlconfig14.7 KB

references/gap_report_template.md

View on GitHub
# Code Gap Analysis Report

<!-- Template. The gap entries below show the format with an illustrative
     resinous-flooring scope; every bracketed value, and every code, section,
     threshold or regulation, is a placeholder. Populate from gap_analysis.yaml
     and jurisdiction.yaml. Never carry a citation from this template into
     the report. -->

**Scope Researched:** [Section number — title (area)]
**Engineer's Question:** Are there code requirements for this scope that are missing?
**Project:** [Name] | [City, State] | [Date]
**Occupancy:** [Group] | **Construction Type:** [Type] | **Sprinklered:** [Yes/No]
**Prepared:** [ISO date]

---

## Applicable Codes (Jurisdiction Confirmed)

| Code | Edition | Adopted By |
|------|---------|-----------|
| [Code name] | [year] | [jurisdiction, date] |
| ... | ... | ... |

---

## Gaps — Action Required

### GAP-001 · HIGH · Confirmed
**Topic:** Slip Resistance
**Code Requirement:** [code and edition] §[section] — [requirement text, with
any threshold exactly as the verified source states it].
**Project Status:** Not addressed. Section 09 67 23 specifies physical properties
(compressive strength, bond strength, Shore D hardness) but contains no COF or
slip resistance requirement and no test method reference.
**Recommended Action:** Add the minimum slip resistance value from the verified
requirement to 09 67 23 §2.1 System Characteristics. Specify the test method
(coordinate with the manufacturer where no industry standard exists for the
specified system and manufacturer test data is the only source). Confirm the AHJ
accepts manufacturer-provided test data.
**Engineer Decision Required:** No (factual addition to spec)
**PE/Architect Decision Required:** No (factual addition to spec)

### GAP-002 · HIGH · Needs Review
**Topic:** Health Department Overlay — Kitchen Complex
**Code Requirement:** [state health department regulation, as verified] —
[requirement text as verified]. Specific requirements may require AHJ
pre-approval of the floor system.
**Project Status:** Not addressed. Rooms [range] (kitchen complex) are within
the resinous flooring scope. No reference to health department requirements found
in 09 67 23 or in the project manual.
**Recommended Action:** Confirm with Owner whether a food service permit is
required for the kitchen complex. If yes, coordinate with the [state] health
department AHJ before the spec is finalized. Obtain written approval of the
specified system from the health department, or identify an alternative system
that has prior approval.
**Engineer Decision Required:** Yes — confirm permit requirement with Owner
**PE/Architect Decision Required:** Yes — AHJ coordination and possible system substitution

---

## Gaps — Confirm and Close

### GAP-003 · MEDIUM · Confirmed
**Topic:** VOC Content Cross-Reference
**Code Requirement:** [VOC regulation adopted for the project] and project Spec
01 61 16 establish VOC content limits for floor coatings applied within the
building envelope.
**Project Status:** Partial. Division 01 Section 01 61 16 addresses VOC limits
globally, but Section 09 67 23 does not reference 01 61 16 and does not
independently state VOC limits for the specified system components.
**Recommended Action:** Add cross-reference to Section 01 61 16 in 09 67 23
§1.1 or §2.1. Obtain VOC content documentation from the manufacturer for all
system components and confirm compliance with limits in 01 61 16.
**Engineer Decision Required:** No (administrative cross-reference)

---

## Uncertain — Requires AHJ Confirmation

| Item | Question | Who Confirms |
|------|----------|-------------|
| [Local jurisdiction] amendments to slip resistance | Does [local jurisdiction] have local amendments that modify [code] §[section]? | Building department AHJ |

---

## Already Addressed — No Action Needed

| Topic | How Addressed | Source |
|-------|---------------|--------|
| Moisture vapor emission testing | ASTM F 1869 (max 7 lb/1000 sf/24hr) and ASTM F 2170 (max 85% RH) both required | 09 67 23 §3.1-B-3 |
| Substrate preparation | Shot-blast per manufacturer; self-priming; patching material specified | 09 67 23 §3.1-B |
| Compressive strength | ASTM C 579 at 7,700 psi after 7 days | 09 67 23 §2.1-D-1 |
| Bond strength | ACI 503R at 400 psi minimum, 100% concrete failure | 09 67 23 §2.1-D-10 |
| Installer qualification | Manufacturer written certification required before production | 09 67 23 §1.3-B-1 |

---

## Documents Reviewed

| Document | Type | Pages / Sheets |
|----------|------|---------------|
| Spec Section 09 67 23 | Specification | Full section |
| Spec Section 01 61 16 | Specification | §1.1, §2.1 |
| Drawing A-3.1 | Finish Schedule | Full sheet |
| [any other documents read] | | |

---

## Disclaimer

This report presents code research findings for informational purposes only.
Gap identifications are based on the documents reviewed and web research
conducted on [date]. All findings require review and confirmation by the
licensed design professional of record. Code interpretations and compliance
determinations are the responsibility of the Architect and Engineer of Record.
Confirm jurisdiction-specific code adoptions and local amendments with the
Authority Having Jurisdiction before finalizing design documents.
brainstormingobra/superpowersYou MUST use this before any creative work - creating features, building components, adding functionality, modifying behavior, or planning anything new, in software or out of it (a talk, a business, a renovation).Stars: 322kUpdated Claude CodeCodexVerifiedInstall
brand-guidelinesanthropics/skillsApplies Anthropic's official brand colors and typography to any sort of artifact that may benefit from having Anthropic's look-and-feel. Use it when brand colors or style guidelines, visual formatting, or company design standards apply.Stars: 197kUpdated Claude CodeCodexVerifiedInstall
frontend-designanthropics/skillsGuidance for distinctive, intentional visual design when building new UI or reshaping an existing one. Helps with aesthetic direction, typography, and making choices that don't read as templated defaults.Stars: 197kUpdated Claude CodeCodexVerifiedInstall
mcp-builderanthropics/skillsGuide for creating high-quality MCP (Model Context Protocol) servers that enable LLMs to interact with external services through well-designed tools. Use when building MCP servers to integrate external APIs or services, whether in Python (FastMCP) or Node/TypeScript (MCP SDK).Stars: 197kUpdated Claude CodeCodexVerifiedInstall