Verified"Implement Statistical Process Control charts to monitor production process stability. Use this skill when the user needs to detect process shifts, set control limits, or distinguish common cause from special cause variation — even if they say 'process monitoring', 'control chart', or 'is our process in control'.".
| File | Kind | Size |
|---|---|---|
| SKILL.md | skill md | 4.3 KB |
| examples/sample_scenario.md | markdown | 5.5 KB |
| references/chart-constants.md | markdown | 7.7 KB |
| references/we-rules.md | markdown | 12.1 KB |
references/we-rules.md
View on GitHub# Western Electric Rules for Out-of-Control Signal Detection
Western Electric rules (WE rules) are pattern tests applied to a control chart to detect non-random signals that a ±3σ limit test alone would miss. Originally published in *Statistical Quality Control Handbook* (AT&T/Western Electric, 1956).
---
## Zone Definitions
Every WE rule depends on dividing the chart into zones relative to the center line (CL):
```
UCL ───────────────────────────── +3σ from CL
Zone A (between +2σ and +3σ)
Zone B (between +1σ and +2σ)
Zone C (between CL and +1σ)
CL ─────────────────────────────
Zone C (between CL and −1σ)
Zone B (between −1σ and −2σ)
Zone A (between −2σ and −3σ)
LCL ───────────────────────────── −3σ from CL
```
For an X-bar chart, compute zone boundaries from the chart's own control limits:
```
+1σ boundary = CL + (UCL − CL) / 3
+2σ boundary = CL + 2 × (UCL − CL) / 3
```
Because UCL = CL + 3σ_X̄, each zone is exactly 1σ_X̄ wide.
---
## The Four Standard WE Rules
### Rule 1 — One point beyond ±3σ (Zone A or beyond)
**Trigger:** any single point falls outside the UCL or LCL.
```
● ← signal (above UCL)
───────────────── UCL
Zone A
───────────────── +2σ
```
**False alarm probability (per point, process in control):** ≈ 0.27%
Expect one false alarm roughly every 370 points.
---
### Rule 2 — Two of three consecutive points in Zone A or beyond (same side)
**Trigger:** within any window of 3 consecutive points, at least 2 fall at +2σ or beyond (or both at −2σ or beyond). Both points must be on the **same side** of CL.
```
Point index: 1 2 3
○ ● ● ← Rule 2 signal at point 3
── ── ──
+1σ +2σ +2σ (● = in Zone A or beyond)
```
**False alarm probability:** ≈ 0.39% per opportunity (each group of 3).
**Common mistake:** triggering this rule when the two Zone A points are on opposite sides of the center line. Opposite-side Zone A points suggest high variance, not a process shift — investigate differently.
---
### Rule 3 — Four of five consecutive points in Zone B or beyond (same side)
**Trigger:** within any window of 5 consecutive points, at least 4 fall at +1σ or beyond (or at −1σ or beyond, same side).
```
Point index: 1 2 3 4 5
● ○ ● ● ● ← Rule 3 signal at point 5
+1σ CL +1σ +1σ +2σ (● = Zone B or beyond on upper side)
```
The 1 point allowed to be in Zone C or the other side gives this rule tolerance for noise.
**False alarm probability:** ≈ 0.54% per opportunity.
---
### Rule 4 — Eight consecutive points on one side of the center line
**Trigger:** 8 (or more) consecutive points all above CL, or all below CL. Points may be anywhere — Zone C through Zone A — as long as none cross the center line.
```
● ● ● ● ● ● ● ● ← all above CL, Rule 4 signal at 8th point
───────────────── CL
```
**False alarm probability:** ≈ 0.39% per opportunity of 8 consecutive points.
**Note on run length:** Some practitioners use 7 instead of 8. The original Western Electric handbook specifies 8. AIAG's SPC manual and Montgomery's *Introduction to Statistical Quality Control* both use 8 for the run-on-one-side rule. If your shop standard uses 7, document it explicitly and apply consistently.
---
## Rules 5–8 (Supplemental — Common Additions)
These are not in the original 1956 WE handbook but appear widely in software (Minitab, JMP) and AIAG SPC references. Use them deliberately; each additional rule increases the false alarm rate.
### Rule 5 — Six points in a row steadily increasing or decreasing (trend)
**Trigger:** 6 consecutive points each strictly higher than the previous (or each strictly lower). Points need not cross zone boundaries.
```
●
●
●
●
●
● ← Rule 5 signal at 6th point
```
**Note:** Some references use 7 points for trend; the SKILL.md uses 7. Whichever you choose, "strictly monotone" is the criterion — ties break the streak.
---
### Rule 6 — Fifteen points in a row within Zone C (both sides)
**Trigger:** 15 consecutive points all between +1σ and −1σ.
This signals *reduced* variation, which sounds good but often indicates:
- Measurement system problem (rounding, limited gauge resolution)
- Data fabrication or improper subgrouping (mixing two processes so within-group variation inflates limits artificially)
- A genuine process improvement — verify by checking raw data and measurement logs
---
### Rule 7 — Fourteen points in a row alternating up and down
**Trigger:** each point alternates direction — up, down, up, down — for 14 consecutive points.
Signals systematic oscillation. Common causes: two alternating machines, two alternating operators, measurement order following a fixture rotation.
---
### Rule 8 — Eight points in a row on both sides of CL with none in Zone C
**Trigger:** 8 consecutive points, all in Zone B or A (above or below), with no point in Zone C.
Signals bimodal data — two process streams mixed into one chart. Check for machine-to-machine, shift-to-shift, or cavity-to-cavity stratification.
---
## False Alarm Rate Accumulates with Rule Count
Each rule independently generates false alarms. Running all 8 rules simultaneously on a 25-subgroup baseline dramatically raises the probability of at least one false positive:
| Rules Active | Approx. False Alarm Rate (per 25 points) |
|---|---|
| Rule 1 only | ~6.7% |
| Rules 1–4 | ~20–25% |
| Rules 1–8 | ~40–50% |
**Practical recommendation:** Use Rules 1–4 as the default set. Add Rules 5–8 only when you have a specific hypothesis (e.g., Rule 6 if you suspect data fabrication, Rule 8 if you suspect multiple process streams).
---
## Detection Algorithm (Pseudocode)
```python
def check_we_rules(values: list[float], cl: float, sigma: float) -> list[dict]:
"""
values: time-ordered sequence of plotted statistics (X-bar, individual, etc.)
cl: center line
sigma: one sigma of the plotted statistic (NOT of raw measurements)
Returns list of signal dicts: {rule, index, value, description}
"""
signals = []
n = len(values)
def zone(v):
"""Returns signed zone number: ±1=C, ±2=B, ±3=A, ±4=beyond UCL/LCL."""
distance = (v - cl) / sigma
sign = 1 if distance >= 0 else -1
abs_d = abs(distance)
if abs_d < 1: return sign * 1
if abs_d < 2: return sign * 2
if abs_d < 3: return sign * 3
return sign * 4
zones = [zone(v) for v in values]
for i in range(n):
# Rule 1: beyond ±3σ
if abs(zones[i]) >= 4:
signals.append({"rule": 1, "index": i, "value": values[i],
"description": "Point beyond 3σ"})
# Rule 2: 2 of 3 in Zone A or beyond, same side
if i >= 2:
w = zones[i-2:i+1]
for side in [1, -1]:
if sum(1 for z in w if z * side >= 3) >= 2:
signals.append({"rule": 2, "index": i, "value": values[i],
"description": f"2 of 3 in Zone A ({'upper' if side>0 else 'lower'})"})
break
# Rule 3: 4 of 5 in Zone B or beyond, same side
if i >= 4:
w = zones[i-4:i+1]
for side in [1, -1]:
if sum(1 for z in w if z * side >= 2) >= 4:
signals.append({"rule": 3, "index": i, "value": values[i],
"description": f"4 of 5 in Zone B ({'upper' if side>0 else 'lower'})"})
break
# Rule 4: 8 consecutive on one side
if i >= 7:
w = zones[i-7:i+1]
if all(z > 0 for z in w) or all(z < 0 for z in w):
signals.append({"rule": 4, "index": i, "value": values[i],
"description": "8 consecutive on one side of CL"})
# Rule 5: 6 consecutive trending (strictly monotone)
if i >= 5:
w = values[i-5:i+1]
if all(w[j] < w[j+1] for j in range(5)) or all(w[j] > w[j+1] for j in range(5)):
signals.append({"rule": 5, "index": i, "value": values[i],
"description": "6 consecutive trend"})
return signals
```
**Important:** `sigma` here is the sigma of the *plotted statistic*, derived from the average range or average standard deviation via the appropriate constant — NOT the raw process σ. For X-bar charts:
```
σ_X̄ = R̄ / (d₂ × √n) [or equivalently (UCL_X̄ − CL) / 3]
```
---
## Worked Example
**Setup:** X-bar chart, n=5 per subgroup, 20 subgroups.
| Constants | Values |
|---|---|
| Grand mean X̄̄ | 50.00 |
| Average range R̄ | 3.60 |
| A₂ (n=5) | 0.577 |
| UCL_X̄ | 50.00 + 0.577×3.60 = **52.08** |
| LCL_X̄ | 50.00 − 0.577×3.60 = **47.92** |
| σ_X̄ | (52.08 − 50.00) / 3 = **0.693** |
Zone boundaries:
| Boundary | Value |
|---|---|
| +3σ (UCL) | 52.08 |
| +2σ | 51.39 |
| +1σ | 50.69 |
| CL | 50.00 |
| −1σ | 49.31 |
| −2σ | 48.61 |
| −3σ (LCL) | 47.92 |
Subgroup X-bar values (selected):
```
Subgroup: 1 2 3 4 5 6 7 8
X-bar: 50.1 50.4 50.8 51.0 51.2 50.9 51.4 51.5
Zone: +C +C +B +B +B +B +B +B
```
**Rule 3 check at subgroup 8** (window: subgroups 4–8):
Zones: +B, +B, +B, +B, +B → 5 of 5 in Zone B or beyond (upper side) → **Rule 3 triggered** (4 of 5 threshold exceeded).
**Rule 4 check at subgroup 8** (window: subgroups 1–8):
All 8 zones are positive → **Rule 4 triggered**.
Both signals fire simultaneously. Rule 4 indicates a sustained shift above CL; Rule 3 is redundant here. Report both but investigate as a single event: the process mean appears to have drifted upward starting around subgroup 3.
---
## Signal Prioritization
When multiple rules fire on the same chart simultaneously:
1. **Rule 1 overrides all others** — a point outside the control limit is the most definitive signal. Start investigation there.
2. **Rules 2 and 3** typically indicate a gradual shift earlier than Rule 4 catches it. If Rule 2 or 3 fires without Rule 1, the shift is subtle — trace back to the earliest point in the triggering window.
3. **Rule 4** (run on one side) confirms a sustained shift that Rules 2/3 already flagged. Reinforces rather than adds new information.
4. **Rules 5–8** are diagnostic — they indicate the *type* of disturbance (trend, stratification, oscillation). Use them to guide root cause hypotheses, not as primary action triggers.
---
## Common Misapplications
**Applying WE rules to R or S charts without adjustment:**
The R chart is skewed (not symmetric around its center line), especially for small n. Rule 4's "8 on one side" is less meaningful because R values cluster below R̄ more often than above. For R and S charts, rely primarily on Rule 1 (beyond UCL) and Rule 5 (trend upward = increasing variation).
**Checking rules against specification limits instead of control limits:**
Zone boundaries must be computed from ±σ_X̄ relative to CL, not from engineering tolerances. This is a direct consequence of the Iron Law in the parent skill.
**Running WE rules during Phase 1 (baseline establishment):**
During baseline, you use WE rules to identify and *remove* out-of-control points before calculating final limits. Removing signals and recalculating is correct here. After limits are established (Phase 2, ongoing monitoring), you do not remove signals — you investigate them.
**Treating every signal as a defect:**
A WE rule signal means "the process behaved unexpectedly — investigate." It does not mean product is out of spec. A signal on the X-bar chart while the R chart is stable suggests a mean shift, not necessarily wider spread. Always look at both charts together.
Related skills
| Skill | Stars | Updated | Works with | Status | Install |
|---|---|---|---|---|---|
| reverse-engineer-anythingmorluto/reaReverse engineer native, managed, Electron/JavaScript, packaged, firmware, and browser targets with REA, and build agent environments (AgentEnv bundles) of web applications from a live instance or a capture, and of Linux desktop apps with a task from a request. Use shipped-artifact or requested runtime evidence to explain features, compare versions, decompile code, or guide a reconstruction. Skip REA for ordinary source-repository architecture analysis. | Stars: 472k | Updated | Claude CodeCodex | Verified | Install |
| diagnosing-superpowersobra/superpowersUse when a superpowers session went wrong and your human partner wants to know why — repeated work, ignored plans, stumbles, poor results, a skill that didn't fire, "it took too long", "why is it so expensive", "what is it doing" — or wants to build a bug report for the superpowers maintainers, for the current session or a past one identified by id or path, on any harness. | Stars: 322k | Updated | Claude CodeCodex | Verified | Install |
| dispatching-parallel-agentsobra/superpowersUse when facing 2+ independent tasks that can be worked on without shared state or sequential dependencies | Stars: 322k | Updated | Claude CodeCodex | Verified | Install |
| executing-plansobra/superpowersUse when executing an implementation plan in the current session as the implementer yourself — your human partner chose inline execution, or no subagent tool is available | Stars: 322k | Updated | Claude CodeCodex | Verified | Install |